A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reliability of a commercially available heterochromatic flicker photometer, the MPS2, for measuring the macular pigment optical density of a Japanese population. | LitMetric

Reliability of a commercially available heterochromatic flicker photometer, the MPS2, for measuring the macular pigment optical density of a Japanese population.

Jpn J Ophthalmol

Department of Medical Spectroscopy, Institute for Medical Photonics Research, Preeminent Medical Photonics Education and Research Center, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan.

Published: July 2018

Purpose: The macular pigment optical density (MPOD) of a Japanese population was measured using a commercially based heterochromatic flicker photometer, the Macular Pigment Screener (MPS2). The objective of the study was to evaluate the accuracy and test-retest reliability of the MPS2 in Asian pigmented eyes.

Study Design: Experimental study to validate the medical instrument in humans.

Methods: Twenty-four healthy Japanese participants with no systemic or eye diseases (men: 13, women: 11; mean [SD] age 38.6 [10.9 years]) were included. The concordance of the MPOD, obtained using the MPS2 and Macular Metrics II (MM2), and the test-retest reliability were examined.

Results: Determination of the MPOD was unsuccessful in 1 participant; thus, the MPOD of 23 participants was analyzed. The mean (SD) MPOD measured with the detail-mode of the MPS2 was 0.63 (0.18) and with that of the MM2, it was 0.72 (0.23). The former was significantly lower than the latter (P = .003, paired t test). The MPOD measured with the MPS2 and the MM2 showed good concordance (r = 0.79, P < .001, Pearson product moment correlation). Bland-Altman analyses showed no systematic errors between the MPS2 and the MM2. The intraclass correlation coefficient over 5 measurement times with the detail-mode of the MPS2 was 0.80, and the mean coefficient of variation was 9.4%.

Conclusion: The high concordance with the MM2 and good test-retest reliability found by this study suggest that the MPS2 is acceptable for use in a Japanese population. However, the mean MPOD yielded by the MPS2 was significantly lower than that yielded by the MM2. Therefore, the MPS2 and MM2 are not interchangeable in a single study.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10384-018-0588-3DOI Listing

Publication Analysis

Top Keywords

macular pigment
12
japanese population
12
test-retest reliability
12
mps2 mm2
12
mps2
11
heterochromatic flicker
8
flicker photometer
8
pigment optical
8
optical density
8
mpod measured
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!