Most HR-pQCT studies examining cortical bone use an automatically generated endocortical contour (AUTO), which is manually corrected if it visually deviates from the apparent endocortical margin (semi-automatic method, S-AUTO). This technique may be prone to operator-related variability and is time consuming. We examined whether the AUTO instead of the S-AUTO method can be used for cortical bone analysis. Fifty scans of the distal radius and tibia from participants of The Maastricht Study were evaluated with AUTO, and subsequently with S-AUTO by three independent operators. AUTO cortical bone parameters were compared to the average parameters obtained by the three operators (S-AUTOmean). All differences in mean cortical bone parameters between AUTO and S-AUTOmean were < 5%, except for lower AUTO cortical porosity of the radius (- 16%) and tibia (- 6%), and cortical pore volume (Ct.Po.V) of the radius (- 7%). The ICC of S-AUTOmean and AUTO was > 0.90 for all parameters, except for cortical pore diameter of the radius (0.79) and tibia (0.74) and Ct.Po.V of the tibia (0.89), without systematic errors on the Bland-Altman plots. The precision errors (RMS-CV%) of the radius parameters between S-AUTOmean and AUTO were comparable to those between the individual operators, whereas the tibia RMS-CV% between S-AUTOmean and AUTO were higher than those of the individual operators. Comparison of the three operators revealed clear inter-operator variability. This study suggests that the AUTO method can be used for cortical bone analysis in a cross-sectional study, but that the absolute values-particularly of the porosity-related parameters-will be lower.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6105151 | PMC |
http://dx.doi.org/10.1007/s00223-018-0416-2 | DOI Listing |
World Neurosurg
December 2024
Saint Joseph University, Beirut, Lebanon.
Background: Burr holes can lead to cranial defects that result in cosmetic and functional issues. Effective reconstruction of these burr holes is crucial for improving patient outcomes, yet there is no consensus on the optimal techniques and materials.
Objective: This systematic review critically evaluates the efficacy and safety of various materials used in neurosurgical practice for burr hole reconstruction.
J Mech Behav Biomed Mater
December 2024
Aix Marseille Université, Université Gustave Eiffel, LBA, Marseille, France. Electronic address:
This study proposes a method for assessing the transverse toughness of human long-bone cortical tissue. The method is based on a three-point bending test of pre-notched femur diaphysis segments, post-processed using the compliance method coupled with numerical simulations. Given the cracking nature of bone and if cracking processes remain confined to the crack tip, it is assumed that the compliance method can be used.
View Article and Find Full Text PDFClin J Sport Med
October 2024
Department of Physical Medicine and Rehabilitation, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.
Objective: To evaluate the trabecular bone score (TBS) Z scores in long-distance runners with bone stress injuries (BSIs) in whom the bone mineral density (BMD) Z score is more than -1.0 (Aim 1) and whether the number of runners with abnormal TBS Z scores would be higher in those with BSI in trabecular-rich sites as compared with cortical-rich sites (Aim 2).
Design: Retrospective cohort study.
PLoS One
December 2024
Department of Materials and Production, Aalborg University, Aalborg, Denmark.
Background: In magnetic resonance imaging (MRI) segmentation research, the choice of sequence influences the segmentation accuracy. This study introduces a method to compare sequences. By aligning sequences with specific segmentation objectives, we provide an example of a comparative analysis of various sequences for knee images.
View Article and Find Full Text PDFArch Orthop Trauma Surg
December 2024
University Hospital Regensburg, Regensburg, Germany.
Introduction: Patellar fractures are rare at 1% incidence of all fractures. However, they can cause significant functional impairments due to the patella's role in knee joint extension. Current scoring systems lack objectivity in assessing patellar healing.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!