Correlation between umbilical arterial pH values and fetal vertebral artery Doppler waveforms at the beginning of the second stage of labor: a pilot prospective study.

J Matern Fetal Neonatal Med

a Department of Morphology, Surgery and Experimental Medicine, Section of Obstetrics and Gynaecology , University of Ferrara, S. Anna University Hospital, Cona, Ferrara , Italy.

Published: September 2019

The aim of this study was to evaluate the association between umbilical arterial pH and fetal vertebral artery Doppler velocimetry waveforms measured at the beginning of the second stage of labor in physiological term pregnancies. This was a prospective cohort study of 250 pregnancies. The resistance index, pulsatility index, and peak systolic velocity were measured. The relationship between the fetal Doppler and the umbilical arterial pH was evaluated. A simple linear regression and a general linear model were used to explore possible correlations of Doppler parameters with fetal and neonatal outcome adjusted for confundents. Umbilical arterial pH values were directly associated with vertebral artery pulsatility index. Fetuses with lower pulsatility index values were at increased risk of a subsequent diagnosis of pathological fetal heart rate tracing patterns (presence of decelerations or reduced variability according to FIGO criteria during the second stage of labor). We estimated a decrease in pulsatility index of 10% in those fetuses destined to show a pathological fetal heart rate tracing. Vertebral artery Doppler waveforms correlates with umbilical pH in normal pregnancies and is also a function of fetal heart rate patterns. If this proportional association would be demonstrated also for abnormal pH values, vertebral artery pulsatility index might be useful to evaluate fetal wellbeing in those cases of suspected hypoxia/academia.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14767058.2018.1458834DOI Listing

Publication Analysis

Top Keywords

vertebral artery
20
umbilical arterial
16
artery doppler
12
second stage
12
stage labor
12
fetal heart
12
heart rate
12
arterial values
8
fetal
8
fetal vertebral
8

Similar Publications

[Spontaneous craniocervical dissection].

Radiologie (Heidelb)

January 2025

Klinik für diagnostische und interventionelle Neuroradiologie, Universitätskliniken des Saarlandes, Kirrberger Str., 66421, Homburg Saar, Deutschland.

Performance: Spontaneous dissections of the cerebral arteries are among the leading causes of stroke in young adults. They result from hemorrhage into the outer layers of the arterial wall, which can lead to stenosis or even complete vessel occlusion. Clinical presentations vary, ranging from localized pain to cerebral ischemic complications.

View Article and Find Full Text PDF

Background: An anomalous left vertebral artery (aLVA) can complicate aortic arch surgery. We examined the safety of various aLVA revascularization strategies during open total arch replacement.

Methods: We retrospectively evaluated 92 patients undergoing total arch replacement from January 2018 to May 2023 and identified 11 patients with aLVA.

View Article and Find Full Text PDF

Influence of Geometric Parameters on The Hemodynamic Characteristics of The Vertebral Artery.

J Biomech Eng

January 2025

State Key Laboratory of Clean Energy Utilization, Zhejiang University, Yuquan Campus, 38 Zheda Road, Hangzhou 310027, Zhejiang, China; Shanghai Institute for Advanced Study of Zhejiang University, Zhangjiang Guochuang Center phase, No.799, Dangui Road, Shanghai 200120, China.

The carotid and vertebral arteries are principal conduits for cerebral blood supply and are common sites for atherosclerotic plaque formation. To date, there has been extensive clinical and hemodynamic reporting on carotid arteries; however, studies focusing on the hemodynamic characteristics of the vertebral artery (VA) are notably scarce. This article presents a systematic analysis of the impact of VA diameter and the angle of divergence from the subclavian artery (SA) on hemodynamic properties, facilitated by the construction of an idealized VA geometric model.

View Article and Find Full Text PDF

Objective: To evaluate the repeatability of AI-based automatic measurement of vertebral and cardiovascular markers on low-dose chest CT.

Methods: We included participants of the population-based Imaging in Lifelines (ImaLife) study with low-dose chest CT at baseline and 3-4 month follow-up. An AI system (AI-Rad Companion chest CT prototype) performed automatic segmentation and quantification of vertebral height and density, aortic diameters, heart volume (cardiac chambers plus pericardial fat), and coronary artery calcium volume (CACV).

View Article and Find Full Text PDF

Objective: To observe the clinical efficacy of 's subcutaneous needling based on "multi-joint muscle spiral balance chain" theory for cervical vertigo (CV) and its effect on blood flow velocity of vertebral artery.

Methods: A total of 60 patients with CV were randomized into a Fu's subcutaneous needling group and a medication group, 30 cases in each one. In the Fu's subcutaneous needling group, 's subcutaneous needling was delivered at Dazhui (GV14), the flexible tube was retained for 5 min after sweeping manipulation, and the treatment was given once every other day, 3 times a week for 3 weeks.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!