A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Liquid chromatography with alkylammonium formate ionic liquid mobile phases and fluorescence detection. | LitMetric

AI Article Synopsis

  • The study investigated the fluorescence detection of pharmaceuticals and tryptophan using alkyl ammonium formate ionic liquids in aqueous solutions.
  • It found that while some drugs like riboflavin and naproxen displayed no fluorescence enhancement, warfarin's fluorescence significantly increased in the presence of ethylammonium formate (EAF) and isopropylammonium formate (IPAF).
  • Additionally, lactate dehydrogenase (LDH) showed improved peak intensity and activity when 6% PEG 8000 was added to the mobile phase during HPLC, but higher concentrations of PEG 8000 were discouraged due to increased viscosity and reduced effectiveness.

Article Abstract

Fluorescence detection of various pharmaceuticals and the amino acid tryptophan (low molecular weight organic compounds) as well as the enzyme lactate dehydrogenase LDH (high molar mass compound) has been studied in aqueous solutions using alkyl ammonium formate ionic liquids as the primary solvent component. It was expected that the high viscosity of such ionic liquid-water mixtures would enhance fluorescence. Pharmaceuticals such as riboflavin and naproxen showed no such enhancement in the presence of ethylammonium formate (EAF) or isopropylammonium formate (IPAF) but the fluorescence of warfarin was substantially enhanced by a factor of 4 with 80% EAF and a factor of 7 with 70% IPAF. However, this improved fluorescence using alkylammonium formates did not seem to be general for other coumarin compounds except for bromadiolone which showed a similar fluorescence enhancement using EAF. Enhancement of tryptophan fluorescence was also seen for both EAF and IPAF. During the reversed phase elution of LDH on a polymeric HPLC column, remarkable enhancements in LDH peak intensity and activity were observed by incorporating 6% PEG 8000 in the organic mobile phase that contained either 20% acetonitrile or IPAF. Using higher concentrations of PEG 8000 is not recommended, not only because of the high viscosity, but also because the stabilizing effect of PEG 8000 is gradually reduced at higher concentrations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2018.03.020DOI Listing

Publication Analysis

Top Keywords

peg 8000
12
formate ionic
8
fluorescence detection
8
high viscosity
8
higher concentrations
8
fluorescence
7
liquid chromatography
4
chromatography alkylammonium
4
formate
4
alkylammonium formate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!