Drug abuse screening with exhaled breath and oral fluid in adults with substance use disorder.

Drug Test Anal

Department of Laboratory Medicine, Division of Clinical Pharmacology, Karolinska Institutet, Karolinska University Hospital, Stockholm, Sweden.

Published: January 2019

In the treatment of substance use disorder, regular laboratory-based testing has the dual purpose of monitoring compliance with the prescribed medication and abstention from medically non-motivated substances (ie, drug abuse screening). The principal specimen for testing is urine, but collection of urine has some disadvantages, for example being more time-consuming and more intrusive compared to other matrices. There is also the risk of adulteration. This project compared exhaled breath and oral fluid as alternative matrices for drug abuse screening in patients with substance use disorder. All 51 subjects included in the study were enrolled at the Drug Addiction Emergency Unit in Stockholm. Exhaled breath, oral fluid, and urine samples were collected together with a self-report. Of all 117 self-reported drug intakes during the previous week, 72% were confirmed in urine, 73% in oral fluid and 39% in exhaled breath. In 31% of the subjects, additional substances other than those self-reported were detected analytically. For substance abuse screening, urine had the highest detection rate for buprenorphine, cannabis, and benzodiazepines, while oral fluid had the highest detection rate for amphetamines and methadone. Exhaled breath showed the highest detection rate of all matrices for cocaine. To identify significant differences in detection rates between the matrices future studies with larger sampling sizes are needed. Both oral fluid and exhaled breath are viable alternative specimens to urine, depending on the circumstances and purpose of the testing.

Download full-text PDF

Source
http://dx.doi.org/10.1002/dta.2384DOI Listing

Publication Analysis

Top Keywords

exhaled breath
24
oral fluid
24
abuse screening
16
drug abuse
12
breath oral
12
substance disorder
12
highest detection
12
detection rate
12
exhaled
6
breath
6

Similar Publications

Background And Purpose: In lung stereotactic body radiation therapy (SBRT) using a breath-holding technique, displacement of tumor during breath-holding is rarely considered. This study used four-dimensional (4D) dose calculation with cine computed tomography (CT) to evaluate the impact of unexpected tumor position displacement during breath-holding on the target dose of lung volumetric modulated arc therapy (VMAT)-SBRT.

Materials And Methods: This study included 20 cases for which tumor position displacement during end-exhalation breath-holding (range: 0.

View Article and Find Full Text PDF

In this study, a non-invasive device based on ultraviolet differential absorption spectroscopy (UV-DOAS) technology for detecting fractional exhaled nitric oxide (FeNO)was developed and clinically validated in patients with various lung diseases. The diagnostic potential of FeNO was explored by analysing subgroups of patients with lung cancer, nodules, and other disease. The results showed that FeNO concentrations were significantly higher in patients with malignant tumours than in healthy controls (p < 0.

View Article and Find Full Text PDF

Introduction: Elexacaftor/tezacaftor/ivacaftor (ETI) has shown significant improvements in pulmonary and nutritional status in persons with cystic fibrosis (pwCF). Less is known about the extrapulmonary impact of ETI and effects on airway microbiology, lung clearance index (LCI) and fraction of exhaled nitric oxide (FeNO).

Methods: A multicentre prospective observational trial, including 79 pwCF ≥ 18 years eligible for ETI.

View Article and Find Full Text PDF

Square and 4-7-8 breathing are popularly promoted by psychotherapists but have little empirical support. We hypothesized that breathing at 6 breaths per minute (bpm) would improve HRV, reduce blood pressure, and improve mood more than either square or 4-7-8 breathing. We also hypothesized square and 4-7-8 breathing would increase end-tidal CO (PETCO).

View Article and Find Full Text PDF

Tobacco use and exposure to tobacco products remain a major public health challenge, even among athletes. This study aimed to evaluate tobacco use and second-hand smoke exposure in athletes through urinary cotinine levels and exhaled air carbon monoxide (CO) measurements. This cross-sectional study included licensed athletes who visited the sports medicine outpatient clinic of a tertiary hospital.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!