The objective of our work was to determine the differences in sensitivity of Hunter and International Commission on Illumination (CIE) methods at 2 different viewer angles (2 and 10°) for measurement of whiteness, red/green, and blue/yellow color of milk-based beverages over a range of composition. Sixty combinations of milk-based beverages were formulated (2 replicates) with a range of fat level from 0.2 to 2%, true protein level from 3 to 5%, and casein as a percent of true protein from 5 to 80% to provide a wide range of milk-based beverage color. In addition, commercial skim, 1 and 2% fat high-temperature, short-time pasteurized fluid milks were analyzed. All beverage formulations were HTST pasteurized and cooled to 4°C before analysis. Color measurement viewer angle (2 vs. 10°) had very little effect on objective color measures of milk-based beverages with a wide range of composition for either the Hunter or CIE color measurement system. Temperature (4, 20, and 50°C) of color measurement had a large effect on the results of color measurement in both the Hunter and CIE measurement systems. The effect of milk beverage temperature on color measurement results was the largest for skim milk and the least for 2% fat milk. This highlights the need for proper control of beverage serving temperature for sensory panel analysis of milk-based beverages with very low fat content and for control of milk temperature when doing objective color analysis for quality control in manufacture of milk-based beverages. The Hunter system of color measurement was more sensitive to differences in whiteness among milk-based beverages than the CIE system, whereas the CIE system was much more sensitive to differences in yellowness among milk-based beverages. There was little difference between the Hunter and CIE system in sensitivity to green/red color of milk-based beverages. In defining milk-based beverage product specifications for objective color measures for dairy product manufacturers, the viewer angle, color measurement system (CIE vs. Hunter), and sample measurement temperature should be specified along with type of illuminant.

Download full-text PDF

Source
http://dx.doi.org/10.3168/jds.2017-14197DOI Listing

Publication Analysis

Top Keywords

milk-based beverages
36
color measurement
32
color
14
objective color
12
hunter cie
12
cie system
12
measurement
11
milk-based
11
beverages
9
cie
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!