Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Although nodule volumetry is a recognized biomarker of malignancy in pulmonary nodules (PNs), caution is needed in its interpretation because of variables such as respiratory volume variation and inter-scan variability of up to 25%. CT Texture Analysis (CTTA) is a potential independent biomarker of malignancy but inter-scan variability and respiratory volume variation has not been assessed.
Methods: In this prospective cohort study, 40 patients (20 with an indeterminate PN and 20 with pulmonary metastases) underwent two LDCTs within a 60-min period (the "Coffee-break") with the aim of assessing the repeatability of CTTA and semi-automated volume measurements. Texture features were extracted from each automatic contoured region surrounding the PN. Patients were also randomized to two inspiratory control groups: normal breath hold, and controlled lung volume to study the influence of inspiratory control on these measurements.
Results: The mean difference in volume between the two scans was 6.3%,SD:29.9%. The textural features displayed 95% CI below ±17.8%, and were less variable than nodule volume (95%CI ± 28.9%). All features had high repeatability, calculated by the concordance correlation coefficient, (0.84 ≤ CCC ≤ 0.99). All measurements were more repeatable for the controlled lung volume group than the normal breath-hold group.
Conclusion: CTTA repeatability was comparable to automatic volumetric measurements, and appears to be improved using controlled volume breath holding.