Measurement of pediatric regional cerebral blood flow from 6 months to 15 years of age in a clinical population.

Eur J Radiol

Univ Rennes1, Faculté de Médecine, F-35043 Rennes, France; INSERM, U 1228, ERL VISAGES, F-35042 Rennes, France; CNRS, IRISA, UMR 6074, F-35042 Rennes, France; INRIA, VISAGES Project-Team, F-35042 Rennes, France; CHU Rennes, Département de Radiologie, F-35033 Rennes, France. Electronic address:

Published: April 2018

AI Article Synopsis

Article Abstract

Objectives: To investigate changes in cerebral blood flow (CBF) in gray matter (GM) between 6 months and 15 years of age and to provide CBF values for the brain, GM, white matter (WM), hemispheres and lobes.

Methods: Between 2013 and 2016, we retrospectively included all clinical MRI examinations with arterial spin labeling (ASL). We excluded subjects with a condition potentially affecting brain perfusion. For each subject, mean values of CBF in the brain, GM, WM, hemispheres and lobes were calculated. GM CBF was fitted using linear, quadratic and cubic polynomial regression against age. Regression models were compared with Akaike's information criterion (AIC), and Likelihood Ratio tests.

Results: 84 children were included (44 females/40 males). Mean CBF values were 64.2 ± 13.8 mL/100 g/min in GM, and 29.3 ± 10.0 mL/100 g/min in WM. The best-fit model of brain perfusion was the cubic polynomial function (AIC = 672.7, versus respectively AIC = 673.9 and AIC = 674.1 with the linear negative function and the quadratic polynomial function). A statistically significant difference between the tested models demonstrating the superiority of the quadratic (p = 0.18) or cubic polynomial model (p = 0.06), over the negative linear regression model was not found. No effect of general anesthesia (p = 0.34) or of gender (p = 0.16) was found.

Conclusion: we provided values for ASL CBF in the brain, GM, WM, hemispheres, and lobes over a wide pediatric age range, approximately showing inverted U-shaped changes in GM perfusion over the course of childhood.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2018.02.003DOI Listing

Publication Analysis

Top Keywords

cubic polynomial
12
cerebral blood
8
blood flow
8
months years
8
years age
8
cbf values
8
brain perfusion
8
cbf brain
8
brain hemispheres
8
hemispheres lobes
8

Similar Publications

Evaluating the genetic components of growth in ostriches with multi-trait and random regression models.

Br Poult Sci

January 2025

Directorate of Animal Sciences, Western Cape Department of Agriculture, Elsenburg, South Africa.

1. The heritability (h) of liveweight (LW) in ostriches can be highly variable, depending on age at recording. The objective of this study was to consider random regression (RR) as an alternative to the multi-trait (MT) structure for the analysis of repeated measures of LW.

View Article and Find Full Text PDF

This study applied cumulative sum (CUSUM) analysis to evaluate trends in operative time and blood loss, It aims to identify key milestones in mastering extraperitoneal single-site robotic-assisted radical prostatectomy (ss-RARP). A cohort of 100 patients who underwent ss-RARP, performed by a single surgeon at the First Affiliated Hospital of Guangzhou Medical University between March 2021 and June 2023, was retrospectively analyzed. To evaluate the learning curve, the CUSUM (Cumulative Sum Control Chart) technique was applied, revealing the progression and variability over time.

View Article and Find Full Text PDF

The rapid acceleration of urbanization and the surge in car ownership necessitate efficient automatic parking solutions in constricted spaces to address the escalating urban parking issue. To optimize space utilization, enhance traffic efficiency, and mitigate accident risks, a method is proposed for smooth, comfortable, and adaptable automatic parking trajectory planning. This study initially employs a hybrid A* algorithm to generate a preliminary path, then fits the velocity and acceleration based on a cubic polynomial.

View Article and Find Full Text PDF

The molecular characteristics and rheological properties of three UHMWPE samples were investigated. The high-temperature GPC method was used for characterizing UHMWPE samples used. The interpretation of the measurement results was based on calibration using the PS standard and the approximation of the PS data by linear and cubic polynomials, as well as on the data for linear PE.

View Article and Find Full Text PDF

A High-Precision Temperature Compensation Method for TMR Weak Current Sensors Based on FPGA.

Micromachines (Basel)

November 2024

State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China.

Tunnel magnetoresistance (TMR) sensors, known for their high sensitivity, efficiency, and compact size, are ideal for detecting weak currents, particularly leakage currents in smart grids. However, temperature variations can negatively impact their accuracy. This work investigates the effects of temperature variations on measurement accuracy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!