Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: Current guidelines recommend administration of unfractionated heparin (UFH) and measurement of activated clotting time (ACT) during endovascular procedures. The aim of this study was to compare ACT and anti-activated factor X (anti-Xa) measurements for monitoring of UFH therapy during an aortic endograft procedure and to assess the association of peak ACT and peak anti-Xa activity with periprocedural bleeding.
Methods: We retrospectively studied 104 patients with aortic aneurysm undergoing endovascular procedures with repeated coagulation measurements. After a UFH bolus, further UFH doses were given according to ACT (target range, ≥250 seconds) in clinical routine, and in parallel to each ACT (Hemochron; Accriva Diagnostics, Newport Beach, Calif) measurement, we determined anti-Xa activity (HemosIL Liquid anti-Xa; Instrumentation Laboratory, Bedford, Mass). UFH redosing was solely based on the ACT measurements. We defined periprocedural bleeding as a drop in hemoglobin level ≥3 g/dL or red blood cell transfusion within 24 hours.
Results: After the initial UFH bolus (median, 67 IU/kg body weight), ACT and anti-Xa measurements showed a weak correlation (r, 0.46; P < .001). Median ACT was 233 seconds (range, 127-374 seconds; interquartile range [IQR], 204-257 seconds); median anti-Xa activity was 1.0 IU/mL (range, 0.5-2.0 IU/mL; IQR, 0.9-1.2 IU/mL). Only 31% of the patients had an ACT value ≥250 seconds, whereas all patients had an anti-Xa activity ≥0.5 IU/mL. Accordingly, ACT triggered redosing of UFH frequently. Consequently, we saw a median total UFH use of 90 IU/kg during the procedure, a median peak ACT of 255 seconds (IQR, 234-273 seconds), and a median peak anti-Xa activity of 1.2 IU/mL (IQR, 1.0-1.4 IU/mL). Periprocedural bleeding occurred in 40 (38%) patients. Peak ACT ≥250 seconds was not associated with bleeding (odds ratio, 1.05; 95% confidence interval, 0.41-2.70; P = .952), whereas peak anti-Xa activity ≥1.2 IU/mL was independently associated with bleeding (odds ratio, 4.95; 95% confidence interval, 1.82-13.48; P = .002). Moreover, no periprocedural thromboembolic event occurred.
Conclusions: In this retrospective study of patients with aortic aneurysm undergoing an endovascular procedure, ACT and anti-Xa measurements showed poor correlation; only increased peak anti-Xa activity was independently associated with periprocedural bleeding, not increased ACT. Our findings also suggest that monitoring of UFH therapy with anti-Xa during aortic endograft procedures may reduce total UFH use. We further speculate that this approach could reduce periprocedural bleeding.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jvs.2017.11.079 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!