During percutaneous transluminal coronary angioplasty (PTCA) frontal ECG leads are routinely monitored. The detection of ST segment deviation during the procedure is important for decisions regarding guiding catheter seating and the timing of balloon inflation and deflation. ST segment deviation appears on intracoronary electrograms in the absence of changes on the surface ECG in many patients, while the reverse is true in some individuals. When a precordial lead is employed, V5 or V6 is most commonly selected. The surface ECG leads most sensitive for monitoring ischemia during left anterior descending angioplasty are not known. In nine lead surface ECGs recorded during balloon inflation, a small degree of ST segment elevation occurred in leads I, aVL, and V5. Lead V2 demonstrated an increase in ST displacement from 0.0 +/- 0.03 mV to 0.29 +/- 0.25 mV during coronary occlusion (p less than 0.01). We conclude that if V5 or V6 is used as a single precordial lead, surface ECG alterations are easily overlooked. During left anterior descending occlusion the most sensitive surface lead is V2. Optimal ECG monitoring during PTCA in some cases should involve surface lead V2 or the intracoronary lead.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.1810130410 | DOI Listing |
BMC Musculoskelet Disord
January 2025
Lecturer of Physical Therapy, Basic Science Department, Faculty of Physical Therapy, Suez University, Suez, Egypt.
Background: pelvis and shoulder are deeply integrated. They are connected by myofascial slings. The pelvic and spinal posture affects the position of the scapula and the activity of its muscles and affects acromio-humeral distance and so that affects shoulder movement.
View Article and Find Full Text PDFInt J Cardiovasc Imaging
January 2025
Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari - Polo di Monserrato s.s. 554 Monserrato (Cagliari), Monserrato, 09045, Italy.
The purpose of this study was to explore the impact of papillary muscle (PPM) infarction on left atrial and ventricular strain parameters in patients with non-anterior ST-segment elevation myocardial infarction (NA-STEMI) using cardiovascular magnetic resonance (CMR). This retrospective study performed CMR scans on 88 consecutive patients with NA-STEMI (68 males, 65 ± 10.05 years).
View Article and Find Full Text PDFPeerJ
January 2025
School of Psychology, Liaoning Normal University, Dalian, Liaoning Province, China.
Objective: This study aimed to examine the impact of social presence on Chinese reading comprehension and associated neural responses.
Methods: Participants tasked with reading Chinese sentences either alone or in the presence of others and subsequently assessing the accuracy of the sentences' meanings. Concurrently, we recorded the participants' electrical brain responses to critical word processing.
JACC Case Rep
January 2025
Department of Cardiovascular Magnetic Resonance, Hôpital Privé Jacques Cartier, Institut Cardiovasculaire Paris Sud, Massy, France.
Although relatively rare, cardiac metastases represent a significant clinical challenge because of their impact on cardiac function and overall patient prognosis. This case presents a rare and atypical presentation of a patient with ventricular arrhythmia revealing a metastatic cancer in the heart. A 59-year-old man with lung cancer was admitted for chest tightness and episodes of syncope.
View Article and Find Full Text PDFJACC Case Rep
January 2025
Department of Cardiovascular Medicine, Richmond Heart & Vascular Associates, Richmond, Virginia, USA.
Transcatheter edge-to-edge repair (TEER) is approved for patients with symptomatic severe mitral regurgitation (MR) who are deemed inoperable or at high surgical risk with life expectancy of more than 1 year, but has also been used off-label in patients with hypertrophic obstructive cardiomyopathy (HOCM) for symptomatic relief who are not candidates for septal reduction therapy. An 83-year-old woman with decompensated heart failure was found to have HOCM with systolic anterior motion of the mitral valve and a large P2 flail segment with ruptured cords. TEER was performed resulting in mild MR and resolution of the prior left ventricular outflow tract gradient.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!