Titanium TSME appliance for patients allergic to nickel.

Eur J Paediatr Dent

MD, DDS - Department of Orthodontics, Fondazione IRCCS Cà Granda - Ospedale Maggiore Policlinico, University of Milan, Milan, Italy.

Published: March 2018

Aim: The aim of this article is to describe the use of a titanium TSME appliance for patients with allergy to resin and nickel. We aim to highlight the optimal way to avoid problems such as stomatitis and peri-labial dermatitis, which generally appear in patients who use traditional orthodontic appliances made in acrylic resin and steel.

Materials And Methods: The construction of a titanium appliance is described and a case treated with it is reported.

Results: The titanium TSME presented in this paper has excellent biocompatibility due to its ability to form superficial oxides, which prevent oxidation and thus corrosion.

Conclusion: The non-allergic properties of titanium allow to propose it as an alternative in patients with a long-term history of allergic reactions to nichel.