A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of chronic kidney disease on Watchman implantation: experience with 300 consecutive left atrial appendage closures at a single center. | LitMetric

The prevalence of chronic kidney disease (CKD) is high in patients with atrial fibrillation (AF). Left atrial appendage closure (LAAC) has been recognized as an efficient alternative to oral anticoagulation for the prevention of thromboembolic events in patients with non-valvular AF (NVAF); however, the long-term safety and efficacy of LAAC in patients with CKD remain unclear. This study was designed to provide data regarding the safety and efficacy of LAAC in NVAF patients with CKD. A real-world analysis of the safety and efficacy of LAAC was performed on a cohort of 300 NVAF patients with or without CKD who underwent LAAC using the Watchman (WM) device at our center. The patients with CKD (n = 151) were significantly older (77.0 ± 7.2 vs. 73.2 ± 7.8 years, respectively, P < 0.0001) and had a higher CHA2DS2-VASc score (4.3 ± 1.5 vs. 3.4 ± 1.4, respectively, P < 0.0001) and HAS-BLED score (4.0 ± 1.0 vs. 3.0 ± 1.0, respectively, P < 0.0001) than the patients without CKD (n = 149). However, there were no differences between groups with respect to the device implant success rate (98.7 vs. 97.3%, respectively, P = 0.446) or severe periprocedural complications within 7 days. The patients were followed up for 637 ± 398 days, and all patients received repeat transesophageal echocardiography (TEE). Thirteen (4.3%) device-related thrombi, 3 (1.0%) ischemic strokes, and 19 (6.3%) non-procedural major bleeding cases were documented, and there were no differences in these complications between groups. The observed rate of all thromboembolic events by Kaplan-Meier analysis decreased by 68.8% (CKD) and 48.6% (non-CKD); moreover, the observed annual rate of bleeding was reduced by 57.5% (CKD) and 11.4% (non-CKD). Our results indicate that LAAC with the WM device is safe and effective in preventing stroke in NVAF patients with and without CKD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6096728PMC
http://dx.doi.org/10.1007/s00380-018-1157-xDOI Listing

Publication Analysis

Top Keywords

patients ckd
16
safety efficacy
12
efficacy laac
12
chronic kidney
8
kidney disease
8
left atrial
8
atrial appendage
8
nvaf patients
8
patients
6
ckd
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!