Image registration assessment in radiotherapy image guidance based on control chart monitoring.

J Med Imaging (Bellingham)

University Health Network, Princess Margaret Cancer Centre, Department of Radiation Physics, Toronto, Ontario, Canada.

Published: April 2018

Image guidance with cone beam computed tomography in radiotherapy can guarantee the precision and accuracy of patient positioning prior to treatment delivery. During the image guidance process, operators need to take great effort to evaluate the image guidance quality before correcting a patient's position. This work proposes an image registration assessment method based on control chart monitoring to reduce the effort taken by the operator. According to the control chart plotted by daily registration scores of each patient, the proposed method can quickly detect both alignment errors and image quality inconsistency. Therefore, the proposed method can provide a clear guideline for the operators to identify unacceptable image quality and unacceptable image registration with minimal effort. Experimental results demonstrate that by using control charts from a clinical database of 10 patients undergoing prostate radiotherapy, the proposed method can quickly identify out-of-control signals and find special cause of out-of-control registration events.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849944PMC
http://dx.doi.org/10.1117/1.JMI.5.2.021221DOI Listing

Publication Analysis

Top Keywords

image guidance
16
image registration
12
control chart
12
proposed method
12
image
9
registration assessment
8
based control
8
chart monitoring
8
image quality
8
unacceptable image
8

Similar Publications

Dual-Locked Enzyme-Activatable Fluorescence Probes for Precise Bioimaging.

ACS Biomater Sci Eng

January 2025

State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 211189, China.

Real-time visualization of endogenous enzymes not only helps reveal the underlying biological principles but also provides pathological information for cancer/disease diagnosis and even treatment guidance. To this end, enzyme-activatable fluorescence probes are frequently fabricated that turn their fluorescence signals "on" exclusively at the enzyme-rich region, thus enabling noninvasive and real-time imaging of enzymes of interest at the molecular level with superior sensitivity and selectivity. However, in a complex biological context, commonly used single enzyme-activatable (i.

View Article and Find Full Text PDF

Characterization of the Micro-Morphology and Compositional Distribution of Chang'e-5 Lunar Soil Mineral Surfaces Using TOF-SIMS.

Adv Sci (Weinh)

January 2025

Experimental Center of Advanced Materials, School of Materials Science & Engineering, Beijing Institute of Technology, Beijing, 100081, China.

The lunar soil samples returned by China's Chang'e-5 (CE-5) contain valuable information on geological evolutions on the Moon. Herein, by employing high-resolution time-of-flight secondary ion mass spectrometry (TOF-SIMS), five rock chip samples from the CE-5 lunar soil are characterized in-depth, which reveal micro-morphological and compositional features. From the elemental/molecular ion distribution images, minerals such as pyroxene, ilmenite, feldspar, K-rich glass, silica, and silicate minerals are identified, along with their occurrence states and distribution results.

View Article and Find Full Text PDF

Stimuli-Responsive Nano Drug Delivery Systems for the Treatment of Neurological Diseases.

Small

January 2025

Molecular Imaging Center, National Center for Drug Screening, Stake Key Laboratory of Chemical Biology, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai, 201203, P. R. China.

Nanomaterials with unparalleled physical and chemical attributes have become a cornerstone in the field of nanomedicine delivery. These materials can be engineered into various functionalized nanocarriers, which have become the focus of research. Stimulus-responsive nanodrug delivery systems (SRDDS) stand out as a sophisticated class of nanocarriers that can release drugs in response to environmental cues.

View Article and Find Full Text PDF

How to perform and evaluate a myocardial perfusion imaging by computed tomography.

Eur Heart J Imaging Methods Pract

January 2025

Perioperative Cardiology and Cardiovascular Imaging Department, Centro Cardiologico Monzino IRCCS, Via C. Parea 4, Milan 20138, Italy.

Stress computed tomography perfusion (CTP) delivers a comprehensive evaluation of both the anatomical and functional aspects in a single examination. It stands out as the only non-invasive technique capable of quantifying coronary stenosis and assessing its functional impact, offering a consolidated diagnostic and management approach for patients with confirmed or suspected coronary artery disease (CAD). This very practical review ('How to.

View Article and Find Full Text PDF

The goal of this study was to summarize the radiological findings and clinical characteristics of mediastinal Ewing sarcoma/primitive neuroectodermal tumor (ES/PNET) in children. A retrospective review was conducted on the clinical and imaging data of 6 children with primary mediastinal ES/PNET that was confirmed by pathology. There were 3 girls and 3 boys in this study, aged between 2 and 11 years old.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!