Timing points used in running races and other competition events are generally based on radio-frequency identification (RFID) technology. Athletes' times are calculated via passive RFID tags and reader kits. Specifically, the reader infrastructure needed is complex and requires the deployment of a mat or ramps which hide the receiver antennae under them. Moreover, with the employed tags, it is not possible to transmit additional and dynamic information such as pulse or oximetry monitoring, alarms, etc. In this paper we present a system based on two low complex schemes allowed in Bluetooth Low Energy (BLE): the non-connectable undirected advertisement process and a modified version of scannable undirected advertisement process using the new capabilities present in Bluetooth 5. After fully describing the system architecture, which allows full real-time position monitoring of the runners using mobile phones on the organizer side and BLE sensors on the participants' side, we derive the mobility patterns of runners and capacity requirements, which are determinant for evaluating the performance of the proposed system. They have been obtained from the analysis of the real data measured in the last Barcelona Marathon. By means of simulations, we demonstrate that, even under disadvantageous conditions (50% error ratio), both schemes perform reliably and are able to detect the 100% of the participants in all the cases. The cell coverage of the system needs to be adjusted when non-connectable process is considered. Nevertheless, through simulation and experimental, we show that the proposed scheme based on the new events available in Bluetooth 5 is clearly the best implementation alternative for all the cases, no matter the coverage area and the runner speed. The proposal widely exceeds the detection requirements of the real scenario, surpassing the measured peaks of 20 sensors per second incoming in the coverage area, moving at speeds that range from 1.5 m/s to 6.25 m/s. The designed real test-bed shows that the scheme is able to detect 72 sensors below 600 ms, fulfilling comfortably the requirements determined for the intended application. The main disadvantage of this system would be that the sensors are active, but we have proved that its consumption can be so low (9.5 µA) that, with a typical button cell, the sensor battery life would be over 10,000 h of use.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5877201 | PMC |
http://dx.doi.org/10.3390/s18030922 | DOI Listing |
JMIR Form Res
December 2024
Child and Adolescent Psychiatry & Psychosocial Care, Amsterdam UMC location Vrije Universiteit Amsterdam, Amsterdam, Netherlands.
Background: Delinquent behavior in adolescence is a prevalent issue, often associated with difficulties across multiple life domains, which in turn perpetuates negative life outcomes. While current treatment programs show partial success in improving behavioral changes and reducing recidivism, comprehensive conclusions regarding the overall efficacy of these interventions have yet to be established. In forensic outpatient settings, the discrepancy between adolescents' limited emotional awareness and the predominant emphasis on cognitive reflection, combined with low treatment adherence, may be factors that undermine treatment efficacy.
View Article and Find Full Text PDFPLoS One
January 2025
Julius Kühn-Institut (JKI), Federal Research Centre for Cultivated Plants, Institute for Epidemiology and Pathogen Diagnostics, Rodent Research, Muenster, Germany.
Small rodents can cause problems on farms such as infrastructure damage, crop losses or pathogen transfer. The latter threatens humans and livestock alike. Frequent contacts between wild rodents and livestock favour pathogen transfer and it is therefore important to understand the movement patterns of small mammals in order to develop strategies to prevent damage and health issues.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Jeanne de Flandre Hospital, Faculté de Médecine, University of Lille, Avenue Eugène Avinée, 59000 Lille, France.
Objective: To develop and validate a device that measures the pressure exerted by forceps on the fetal head for clinical use.
Background: The lack of clinical tools to quantify forceps pressure on the fetal head may impact maternal and neonatal outcomes. Existing studies have not measured the direct contact pressure between forceps blades and the fetal head, highlighting the need for innovation.
Sensors (Basel)
November 2024
Transport Faculty, National University of Science and Technology POLITEHNICA Bucharest, 060042 Bucharest, Romania.
Integrating road vehicles into broader Internet of Things (IoT) ecosystems is an important step in the development of fully connected and smart transportation systems. This research explores the potential of using communication technologies that achieve a balance between low-power and long-range (LPLR) capabilities while remaining cost-effective, specifically Bluetooth Classic BR-EDR, Bluetooth LE, ZigBee, nRF24, and LoRa-for Vehicle-to-Infrastructure (V2I) and Vehicle-to-IoT (V2IoT) ecosystem interactions. During this research, several field tests were conducted employing different types of communication modules, across three distinct environments: an open-field inter-urban road, a forest inter-urban road, and an urban road.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!