We report γ-ray dosimeters using carbon nanotubes wrapped with metastable poly(olefin sulfone)s (POSs) that readily depolymerize when exposed to ionizing radiation. New POSs, designed for wrapping single-walled carbon nanotubes (SWCNTs), are synthesized and characterized. The resulting POS-SWCNT composites serve as the active transducer in a novel class of γ-ray dosimeters. In our devices, polymer degradation results in immediate changes in the electronic potential of the POS-SWCNT active layers by decreasing the electron tunneling barriers between individualized tubes and by creating enhanced cofacial π-π electron contacts. By incorporating the SWCNT-POS composites into small resistive device platforms, we establish a rare example of real-time detection and dosimetry of radioactive ionizing radiation using organic-based materials. We show that the sensitivity of our platform closely depends on the intrinsic stability of the polymer matrix, the opacity toward γ-rays, and the dispersion efficiency (i.e., the individualization and isolation of the individual SWCNT charge carriers). Resistance decreases up to 65% after irradiation with a 40 krad dose demonstrates the high sensitivity of this novel class of γ-ray sensors. In addition, the detection mechanism was evaluated using a commercial capacitive device platform. The ease of fabrication and low power consumption of these small and inexpensive sensor platforms combined with appealing sensitivity parameters establishes the potential of the poly(olefin sulfone)-SWCNT composites to serve as a new transduction material in γ-ray sensor applications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6372115 | PMC |
http://dx.doi.org/10.1021/acssensors.8b00108 | DOI Listing |
Cureus
December 2024
Department of Oral Medicine and Radiology, Drs Sudha and Nageswara Rao Siddhartha Institute of Dental Sciences, Vijayawada, IND.
Background The thyroid gland is the most susceptible organ to radiation during the exposure of teeth because the thyroid area appears to be within the primary beam, and the dose levels are relatively high even after using collimation. This study aims to develop an eco-friendly thyroid shield by reusing lead foils from intra-oral periapical radiographic films and evaluate its effectiveness in intraoral radiography. Methods A total of 16 patients undergoing endodontic procedures who gave written consent to participate in the study were included and divided into four categories: anterior, canine, premolar, and molar.
View Article and Find Full Text PDFRadiat Environ Biophys
January 2025
Laboratory of Health Sciences and Technologies, Higher Institute of Health Sciences, Hassan First University, Settat, Morocco.
This study assesses radiation doses in multi-slice computed tomography (CT) using epoxy resin and PMMA phantoms, focusing on the relationship between TAR (tissue air ratio) and kilovoltage peak (kVp). The research was conducted using a Hitachi Supria 16-slice CT scanner. An epoxy resin phantom was fabricated from commercially available materials, to simulate human tissue.
View Article and Find Full Text PDFHeliyon
January 2025
Department of Medical Laboratories, College of Applied Medical Sciences, Qassim University, Buraydah 51452, Saudi Arabia.
Purpose: Due to the extensive use of radiation in various fields, such as food safety, sterilizing surgical materials, and medical diagnostics, it is essential to minimize radiation exposure for both patients and healthcare professionals, even at low doses. To meet this requirement, a composite film has been developed using polyvinyl alcohol (PVA) polymer and nitro blue tetrazolium (NBT) dye to measure low radiation doses effectively.
Methods: Various concentrations of NBT dye (ranging from 0.
Cancer Manag Res
January 2025
School of Physics, Universiti Sains Malaysia, Penang, 11800 Gelugor, Malaysia.
Introduction: Breast cancer is a significant worldwide health issue, particularly in Jordan, where early detection via mammography is essential for effective disease management. Despite the little radiation risk associated with mammography, it is crucial to monitor radiation exposure to guarantee patient safety. This study intends to assess skin entrance exposure and compute the Mean Glandular Dose (MGD) in mammography units to determine adherence to established criteria and pinpoint areas for enhancement.
View Article and Find Full Text PDFTech Innov Patient Support Radiat Oncol
March 2025
Graduate School of Biomedical Sciences, Tokushima University, Tokushima, Tokushima 770-8503, Japan.
Purpose: This study aims to compare treatment plans created using RapidPlan and PlanIQ for twelve patients with prostate cancer, focusing on dose uniformity, dose reduction to organs at risk (OARs), plan complexity, and dose verification accuracy. The goal is to identify the tool that demonstrates superior performance in achieving uniform target dose distribution and reducing OAR dose, while ensuring accurate dose verification.
Methods: Dose uniformity in the planning target volume, excluding the rectum, and dose reduction in the OARs (the rectum and bladder) were assessed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!