Objective: To correlate clinicoradiologic and pathological features of breast cancer with quantitative and qualitative shear wave elastographic parameters.
Methods: 82 breast cancers in 75 patients examined by B-mode ultrasound and shear wave elastography (SWE) were included. SWE parameters including quantitative factors [maximum elasticity (E), mean elasticity (E), elasticity ratio (E) and standard deviation (SD)] and qualitative factor (color pattern) were correlated with clinicoradiologic and pathological features using univariate and multivariate linear regression analyses.
Results: Presence of symptoms and larger tumor size on ultrasound were significantly associated with higher E, E, E, and SD (all p < 0.05) on univariate analysis. Older age was significantly correlated with higher E and E (p = 0.026, 0.018). Lymphovascular invasion and larger pathologic size were significantly associated with higher E (p = 0.036, 0.043) and SD (p < 0.001, 0.019). No immunohistochemical biomarkers were significantly correlated with SWE parameters. There was no significant correlation between color pattern and any variable. Multivariate logistic regression analysis showed that the symptom, tumor size on ultrasound and lymphovascular invasion were independent factors that influenced the SWE values.
Conclusion: Tumor stiffness as measured by SWE and B-mode ultrasound could help predict cancer prognosis. Advances in knowledge: Clinicoradiologic factors had correlation with quantitative and qualitative SWE parameters. Using SWE parameters and B-mode ultrasound, we can predict breast cancer prognosis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6223289 | PMC |
http://dx.doi.org/10.1259/bjr.20170830 | DOI Listing |
Int J Womens Health
December 2024
Department of Ultrasound Imaging, The First Affiliated Hospital of Wenzhou Medical University, WenZhou, ZheJiang, 325000, People's Republic of China.
Objective: To analyse the parameters of shear wave elastography (SWE) and contrast-enhanced ultrasound (CEUS) in breast non-mass-like lesions (NMLs) and to evaluate the added diagnostic value of SWE and CEUS when combined with B-mode ultrasound (US) for differentiating NMLs.
Methods: A total of 118 NMLs from 115 patients underwent US, SWE, and CEUS examinations. The SWE parameter with the highest areas under the receiver operating characteristic (ROC) curves (Az) and independent variables of CEUS obtained by logistic regression were used to adjust the BI-RADS-US (Breast Imaging Reporting and Data System for Ultrasound) classification.
Ann Hepatol
December 2024
Institute of Laboratory Medicine, University Hospital Ostrava,17. Listopadu 1740, 70800, Ostrava, Czech Republic; Department of Physiology and Pathophysiology, Faculty of Medicine, University of Ostrava, Syllabova 19, 70030, Ostrava, Czech Republic. Electronic address:
Introduction And Objectives: With increases in obesity and metabolic syndrome because of lifestyle-related factors, the prevalence of non-alcoholic fatty liver disease (NAFLD) also is increasing worldwide. In a subset of patients with NAFLD, an inflammatory process arises in the steatotic liver, known as non-alcoholic steatohepatitis, that leads to liver fibrosis and liver cirrhosis. In selected patients with obesity, bariatric surgery, and bariatric endoscopy are important therapeutic options.
View Article and Find Full Text PDFInt J Nephrol Renovasc Dis
December 2024
Department of Radiodiagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education (MAHE), Manipal, Karnataka, India.
Purpose And Motivation: Chronic kidney disease (CKD) is a major global public health problem with eventual progression to end-stage renal disease which tends to increase kidney stiffness. Shear wave elastography (SWE) is a recently developed ultrasound based technique which can be used to assess tissue stiffness noninvasively. The aim of this study was to evaluate the potential diagnostic value of SWE to assess renal parenchymal stiffness in CKD and its correlation with estimated glomerular filtration rate (eGFR), which may be used as a marker for detecting and staging CKD.
View Article and Find Full Text PDFOncol Lett
February 2025
Department of Ultrasound, Yancheng No. 1 People's Hospital (The First People's Hospital of Yancheng), Affiliated Hospital of Medical School, Nanjing University, Yancheng, Jiangsu 224000, P.R. China.
Breast cancer is one of the most common malignancies affecting women worldwide, and an early diagnosis is critical for improving prognosis. The present study aimed to investigate the diagnostic value of mammography (MG) combined with ultrasound shear wave elastography (SWE) and magnetic resonance imaging (MRI) for the early screening of breast cancer. Patients with breast tumors who underwent lumpectomy at a single hospital between December 2021 and January 2023 were selected and categorized into a benign or malignant group based on pathological findings.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Nuclear Medicine, University of Szeged, Szeged, Hungary.
Background: At least 20% of the future liver remnant must function properly after liver tumor resection to avoid post-hepatectomy liver failure (PHLF). [Tc]Tc-mebrofenin scintigraphy and SPECT are unique noninvasive, quantitative methods for evaluating liver function via hepatocellular bilirubin clearance.
Aim: To evaluate the value of dynamic [Tc]Tc-mebrofenin SPECT/CT parameters for predicting clinically relevant PHLF according to the ISGLS criteria.