Evaluation of Coronary Artery Stenosis by Quantitative Flow Ratio During Invasive Coronary Angiography: The WIFI II Study (Wire-Free Functional Imaging II).

Circ Cardiovasc Imaging

From the Department of Cardiology, Aarhus University Hospital, Skejby, Denmark (J.W., S.W., M.-B.V., B.K.A., E.N.H., C.F.M., L.N.A., J.K.S., S.D.K., M.M., A.K., C.J.T., L.R.K., L.J., J.F.L., H.E.B., E.H.C., N.R.H.); Med-X Research Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, China (S.T., Y.Z.); Department of Cardiology, Hospitalsenheden Vest, Regionshospitalet Herning, Denmark (L.N., M.B.); Department of Cardiology, Hospitalsenheden Midt, Regionshospitalet Silkeborg, Denmark (J.K.J.); and Department of Radiology, Leiden University Medical Center, The Netherlands (J.H.C.R.).

Published: March 2018

Background: Quantitative flow ratio (QFR) is a novel diagnostic modality for functional testing of coronary artery stenosis without the use of pressure wires and induction of hyperemia. QFR is based on computation of standard invasive coronary angiographic imaging. The purpose of WIFI II (Wire-Free Functional Imaging II) was to evaluate the feasibility and diagnostic performance of QFR in unselected consecutive patients.

Methods And Results: WIFI II was a predefined substudy to the Dan-NICAD study (Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease), referring 362 consecutive patients with suspected coronary artery disease on coronary computed tomographic angiography for diagnostic invasive coronary angiography. Fractional flow reserve (FFR) was measured in all segments with 30% to 90% diameter stenosis. Blinded observers calculated QFR (Medis Medical Imaging bv, The Netherlands) for comparison with FFR. FFR was measured in 292 lesions from 191 patients. Ten (5%) and 9 patients (5%) were excluded because of FFR and angiographic core laboratory criteria, respectively. QFR was successfully computed in 240 out of 255 lesions (94%) with a mean diameter stenosis of 50±12%. Mean difference between FFR and QFR was 0.01±0.08. QFR correctly classified 83% of the lesions using FFR with cutoff at 0.80 as reference standard. The area under the receiver operating characteristic curve was 0.86 (95% confidence interval, 0.81-0.91) with a sensitivity, specificity, negative predictive value, and positive predictive value of 77%, 86%, 75%, and 87%, respectively. A QFR-FFR hybrid approach based on the present results enables wire-free and adenosine-free procedures in 68% of cases.

Conclusions: Functional lesion evaluation by QFR assessment showed good agreement and diagnostic accuracy compared with FFR. Studies comparing clinical outcome after QFR- and FFR-based diagnostic strategies are required.

Clinical Trial Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02264717.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5895131PMC
http://dx.doi.org/10.1161/CIRCIMAGING.117.007107DOI Listing

Publication Analysis

Top Keywords

coronary artery
16
invasive coronary
12
artery stenosis
8
quantitative flow
8
flow ratio
8
coronary angiography
8
wire-free functional
8
functional imaging
8
qfr
8
testing coronary
8

Similar Publications

Bombay blood and the 'Swab-Lite' method of blood conservation.

Asian Cardiovasc Thorac Ann

January 2025

Departments of Cardiac Surgery, HMC, Doha, Qatar.

Bombay blood (hh blood) is a rare blood group (4 per million), with no expression of the H antigen present in blood group O. Bombay blood patients can only receive Bombay blood, with autodonation used for elective surgery. We present a Bombay patient (haemoglobin 12.

View Article and Find Full Text PDF

Performance of the High-STEACS Early Rule Out Pathway Using hs-cTnT at 30 Days in a Multisite US Cohort.

Circ Cardiovasc Qual Outcomes

January 2025

Department of Emergency Medicine, Wake Forest University School of Medicine, Winston-Salem, NC. (N.P.A., A.C.S., M.W.S., M.J.M., T.H., S.A.M.).

Background: The High-STEACS (High-Sensitivity Troponin in the Evaluation of Patients With Acute Coronary Syndrome) pathway risk stratifies emergency department patients with possible acute coronary syndrome. This study aims to determine if the High-STEACS hs-cTnT (high-sensitivity cardiac troponin T) pathway can achieve the ≥99% negative predictive value (NPV) safety threshold for 30-day cardiac death or myocardial infarction (CDMI) in a multisite US cohort of patients with and without known coronary artery disease (CAD).

Methods: A secondary analysis of the STOP-CP (High-Sensitivity Cardiac Troponin T [Gen 5 STAT Assay] to Optimize Chest Pain Risk Stratification) cohort, which enrolled adult emergency department patients with possible acute coronary syndrome at 8 US sites (January 25, 2017-September 6, 2018).

View Article and Find Full Text PDF

Background: Limited large-scale, real-world data exist on the prevalence and clinical impact of discordance between fractional flow reserve (FFR) and nonhyperemic pressure ratios (NHPRs).

Methods: The J-PRIDE registry (Clinical Outcomes of Japanese Patients With Coronary Artery Disease Assessed by Resting Indices and Fractional Flow Reserve: A Prospective Multicenter Registry) prospectively enrolled 4304 lesions in 3200 patients from 20 Japanese centers. The lesions were classified into FFR+/NHPR-, FFR-/NHPR+, FFR+/NHPR+, or FFR-/NHPR groups according to cutoff values of 0.

View Article and Find Full Text PDF

Background: Gut microbiota-derived metabolite Trimethylamine-N-oxide (TMAO) is increasingly recognized as a potential novel prognostic biomarker for cardiovascular disease. Our research work aimed to investigate the potential utility of TMAO measurement in patients with STelevation Myocardial Infarction (STEMI).

Methods: We performed a systematic literature search in PubMed from inception to the 1st of February 2024 to identify all studies examining the association between plasma TMAO levels and disease complexity or clinical outcomes in STEMI patients.

View Article and Find Full Text PDF

Objective: Coronary artery disease (CAD) remains a significant global health burden, characterized by the narrowing or blockage of coronary arteries. Treatment decisions are often guided by angiography-based scoring systems, such as the Synergy Between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery (SYNTAX) and Gensini scores, although these require invasive procedures. This study explores the potential of electrocardiography (ECG) as a noninvasive diagnostic tool for predicting CAD severity, alongside traditional risk factors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!