Objective: To probe the relationship among cement volume/fraction, imaging features of cement distribution, and pain relief and then to evaluate the optimal volume during percutaneous vertebroplasty.

Methods: From January 2014 to January 2017, a total of 130 patients eligible for inclusion criteria were enrolled in this prospective cohort study. According to the different degrees of pain relief, cement leakage, and cement distribution, all patients were allocated to 2 groups. Clinical and radiologic characteristics were assessed to identify independent factors influencing pain relief, cement leakage, and cement distribution, including age, sex, fracture age, bone mineral density, operation time, fracture level, fracture type, modified semiquantitative severity grade, intravertebral cleft, cortical disruption in the vertebral wall, endplate disruption, type of nutrient foramen, fractured vertebral body volume, intravertebral cement volume, and volume fraction. A receiver operating characteristic curve was used to analyze the diagnostic value of the cement volume/fraction and then to obtain the optional cut-off value.

Results: The preoperative visual analog scale scores in the responders versus nonresponders patient groups were 7.37 ± 0.61 versus 7.87 ± 0.92 and the postoperative VAS scores in the responders versus nonresponders were 2.04 ± 0.61 versus 4.33 ± 0.49 at 1 week. There were no independent factors influencing pain relief. There were 95 (73.08%) patients who experienced cement leakage, and cortical disruption in the vertebral wall and cement fraction percentage were identified as independent risk factors by binary logistic regression analysis (adjusted odds ratio [OR] 2.935, 95% confidence interval [95% CI] 1.214-7.092, P = 0.017); (adjusted OR 1.134, 95% CI 1.026-1.254, P = 0.014). The area under the receiver-operating characteristic curve of volume fraction (VF%) was 0.658 (95% CI 0.549-0.768, P = 0.006 < 0.05). The cut-off value of VF% for cement leakage was 21.545%, with a sensitivity of 69.50% and a specificity of 60.00%. The incidence of favorable cement distribution was 74.62% (97/130), and VF% were identified as independent protective factors (adjusted OR 1.185, 95% CI 1.067-1.317, P = 0.002) The area under the receiver-operating characteristic curve of VF% was 0.686 (95% CI 0.571-0.802, P = 0.001 < 0.05). The cut-off value of VF% to reach a favorable cement distribution was 19.78%, with a sensitivity of 86.60% and a specificity of 51.50%.

Conclusions: In osteoporotic vertebral compression fracture with mild/moderate fracture severity at the single thoracolumbar level, the intravertebral cement volume of 4-6 mL could relieve pain rapidly. The optimal VF% was 19.78%, which could achieve satisfactory cement distribution. With the increase of VF%, the incidence of cement leakage would also increase.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2018.03.050DOI Listing

Publication Analysis

Top Keywords

cement leakage
24
cement distribution
24
pain relief
20
cement
18
volume fraction
12
relief cement
12
characteristic curve
12
optimal volume
8
prospective cohort
8
cohort study
8

Similar Publications

Detecting asymptomatic cement pulmonary embolisms following vertebral augmentation using dual-energy computed tomography pulmonary angiography.

J Formos Med Assoc

January 2025

Department of Medical Imaging, National Taiwan University Hospital, Taipei, Taiwan; Department of Medical Imaging, National Taiwan University Cancer Center, Taipei, Taiwan.

Background And Purpose: Dual-energy computed tomography (DECT) pulmonary angiography can reliably detect cement pulmonary embolisms (CPEs) and parenchymal perfusion defects. This prospective observational study investigated CPEs in asymptomatic patients using DECT.

Methods: We enrolled 42 patients who underwent vertebroplasty or received cement screws for vertebral augmentation, examining them using spinal computed tomography and DECT pulmonary angiography.

View Article and Find Full Text PDF

Objective: To observe the clinical outcomes of anterior approach for the revision surgery following unsuccessful bone cement augmentation in osteoporotic vertebral compression fractures.

Methods: A total of 10 patients who experienced unsuccessful bone cement augmentation underwent anterior revision surgery between January 2020 and December 2021. There were 2 males and 8 females.

View Article and Find Full Text PDF

Percutaneous vertebroplasty (PVP) is a widely utilized minimally invasive technique originally developed for the treatment of vertebral compression fractures. It has since expanded to treat osteoporotic vertebral compression fractures, pathologic vertebral fractures resulting from primary or secondary spinal tumors, and traumatic spinal fractures. Despite its benefits, PVP is associated with significant complications, the most common of which is bone cement leakage.

View Article and Find Full Text PDF

Cement-augmented pedicle screw instrumentation is a widely accepted method for managing osteoporotic fractures, but it carries inherent risks, particularly related to cement leakage and embolism. This study aimed to analyze a clinical case of complications following cement fixation and provide a detailed review of relevant literature. A 70-year-old patient underwent transpedicular screw instrumentation from L2-L4 with polymethyl methacrylate augmentation, which resulted in cement leakage into the spinal canal and subsequent pulmonary embolism.

View Article and Find Full Text PDF

Impact of surface conditioner phytic acid (IP6) Er,Cr:YSGG laser (ECYL) methylene blue photodynamic therapy (MB-PDT) on the microleakage and shear bond strength (SBS) of resin-modified glass ionomer cement (RMGIC) to primary sound dentin. Overall, 80 extracted sound primary molars were collected followed by their submergence in self-cure acrylic resin. The dentin surface was exposed and made flat and was assigned into four groups based on the surface conditioning.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!