Background And Objectives: Laparoscopic paraesophageal hernia repair (LPEHR) is the new standard, but the use of mesh is still debated. Biologic mesh has shown great promise, but only the U-shaped onlay has been extensively studied. Postoperative dysphagia has historically been a concern with the use of synthetic keyhole mesh and subsequently slowed its adoption. The purpose of our study was to identify the incidence of postoperative dysphagia in a series of patients who underwent laparoscopic paraesophageal hernia repair with novel placement of keyhole biologic mesh.
Methods: Thirty consecutive patients who underwent hernia repair with primary suture cruroplasty and human acellular dermal matrix keyhole mesh reinforcement were reviewed over a 2-year period. All procedures were performed at a single institution. Postoperative symptoms were retrospectively identified. Any postoperative hernia on imaging was defined as radiographic recurrence.
Results: Of the 30 consecutive patients who underwent hernia repair, 3 (10%) had mild preoperative dysphagia. The number remained unchanged after LPEHR with keyhole mesh. Return of mild reflux symptoms occurred in 6 (20%) patients. Repeat imaging was performed in 11 patients (37%) at an average of 8 months with 2 slight recurrences. All hernias were classified on preoperative imaging as large hiatal hernias. There were no postoperative complications.
Conclusion: Laparoscopic paraesophageal hernia repair with biologic keyhole mesh reinforcement has a low recurrence rate and no increase in postoperative dysphagia. The traditional belief that keyhole mesh has a higher incidence of dysphagia was not evident in this series.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5855522 | PMC |
http://dx.doi.org/10.4293/JSLS.2017.00086 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!