Differences in lung function after the use of 2 extrication systems: a randomized crossover trial.

Emergencias

Gerencia de Urgencias y Emergencias 061 de la Región de Murcia. Universidad Católica de Murcia (UCAM). Murcia, España.

Published: May 2019

Objectives: The main purpose of this study in healthy volunteers was to compare the lung function effects of 2 extrication devices that use spinal vests: the Kendrick Extrication Device (KED) and the Ferno KED-XT board.

Material And Methods: Randomized crossover trial in 50 healthy adult volunteers. The subjects were placed in the KED and KED-XT devices for 5 minutes each and rested for 10 minutes between devices. Assignment to the first device was randomized. Each subject underwent spirometry at baseline and after placement of each device. The subjects were seated for all tests. The main outcome measures were the mean absolute differences between baseline and other measurements of forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), and the FVC/FEV1 ratio.

Results: Use of the devices led to statistically significant mean decreases from baseline FVC (KED-XT, -0.48 L; 95% CI, -0.16 to -0.81 L [P=.016] and KED, -0.79 L; 95% CI, -0.44 to -1.13 L [P<.001]) and from baseline FEV1 (KED-XT, -0.35 L/s; 95% CI, -0.14 to -0.56 L/s [P=.002] and KED, -0.52 L/s; 95% CI, -0.31 to -0.72 L/s [P<.001]). The decrease in FVC was greater after use of the KED device (mean difference, KED vs KED-XT, -0.30 L; 95% CI, -0.08 to -0.69 L [P<.016]).

Conclusion: The use of spinal vests leads to decreases in lung function variables. The KED vest causes a greater decrease in FVC than the new KED-XT board, possibly because the crossed straps on the board compress the abdomen less.

Download full-text PDF

Source

Publication Analysis

Top Keywords

lung function
8
randomized crossover
8
crossover trial
8
differences lung
4
function extrication
4
extrication systems
4
systems randomized
4
trial objectives
4
objectives main
4
main purpose
4

Similar Publications

Objective: To determine the impact of prolonged storage of donor lungs at 10°C of up to 24h on outcome after lung transplantation.

Background: An increasing body of evidence suggests 10°C as the optimal storage temperature for donor lungs. A recent study showed that cold ischemic times can be safely expanded to >12h when lungs are stored at 10°C.

View Article and Find Full Text PDF

Background: The relationship between diabetes mellitus (DM) and asthma is complex and can impact disease trajectories.

Aim: To explore the bidirectional influences between the two conditions on clinical outcomes and disease control.

Methods: We systematically reviewed the literature on the relationship between DM and asthma, focusing on their impacts, mechanisms, and therapeutic implications.

View Article and Find Full Text PDF

The purpose of this work is to evaluate the feasibility of lung imaging using 3D electrical impedance tomography (EIT) during spontaneous breathing trials (SBTs) in patients with acute hypoxic respiratory failure. EIT is a noninvasive, nonionizing, real-time functional imaging technique, suitable for bedside monitoring in critically ill patients. EIT data were collected in 24 mechanically ventilated patients immediately preceding and during a SBT on two rows of 16 electrodes using a simultaneous multicurrent source EIT system for 3D imaging.

View Article and Find Full Text PDF

Background: People living with HIV (PLWH) have a higher prevalence of diastolic dysfunction and left ventricular hypertrophy (LVH) in cross-sectional studies. Longitudinal data are lacking, especially from Africa.

Objectives: The aim was to examine: 1) the incidence of diastolic dysfunction in PLWH compared to community controls in Tanzania; 2) the progression of diastolic function and LVH in PLWH after antiretroviral therapy initiation; and 3) traditional, endemic, and HIV-specific risk factors for diastolic function and LVH.

View Article and Find Full Text PDF

Echocardiography of the right heart in pulmonary arterial hypertension: insights from the ULTRA RIGHT VALUE study.

Eur Heart J Imaging Methods Pract

January 2025

Department of Clinical Internal, Anesthesiological and Cardiovascular Sciences, Sapienza University of Rome, Viale del Policlinico 155, Rome 00161, Italy.

Aims: Outcome in pulmonary arterial hypertension (PAH) is determined by right ventricular (RV) function adaptation to increased afterload. Echocardiography is easily available to assist bedside evaluation of the RV. However, no agreement exists about the feasibility and most relevant measurements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!