A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Role of Heat-Tolerant Endotoxin-Retentive Ultrafilters (UFs) for the Remediation of Reverse Osmosis (RO) Plants Employed for Surgical Hand Antisepsis Using Periodic Thermal Disinfection-A Ten Year Longitudinal Experience Study in the Operating Theater. | LitMetric

AI Article Synopsis

  • The study explored the effectiveness of heat-tolerant ultrafilters (UFs) in cleaning up reverse osmosis (RO) water plants that are used for surgical hand antisepsis.
  • After retrofitting UFs in 2010, the levels of endotoxin in the water decreased significantly in RO plant A and were mostly kept below harmful levels.
  • The results indicated that combining UFs with regular thermal disinfection improved the remediation process of the RO plants.

Article Abstract

Recently, the use of filters has come into light for sanitizing water plants. This study investigated the role of heat-tolerant ultrafilters (UFs) for the remediation of reverse osmosis (RO) plants using periodic thermal disinfection. Two completely identical RO plants (RO plants A and B) were installed in 2006 for surgical hand antisepsis in the operating theater. RO water was stored in the 300 L storage tank and recirculated in the 190 meter-long loop delivering water to 12 faucets in each RO plant. Periodic thermal disinfection came into practice periodically when a UF module was retrofitted to the recirculation loop of each RO plant in 2010. Endotoxin was monitored closely before and after thermal disinfection. Before UF modules were retrofitted, endotoxin increased to a maximum of 0.301 EU/mL in RO plant A and 1.446 EU/mL in RO plant B after thermal disinfection, respectively. Since a UF module was retrofitted to each RO plant in 2010, endotoxin has been continuously below 0.025 EU/mL in RO plant A and exceeded this level five times in RO plant B. On one occasion, endotoxin increased in all samples collected simultaneously after solenoid valves were replaced in the recirculation loop near the air conditioner outlet. At this time, the inside of the pipework was exposed to the ventilation airflow. After the valves were replaced again, this time with the workplace isolated using a curing sheet, endotoxin decreased. On the other occasions, endotoxin increased only in one sample and decreased after thermal disinfection. Annually replaced UF modules were examined twice for estimating the amounts of immobilized endotoxin. The estimated amounts decreased in 2013 by the order of 10 in comparison with those in 2011 in both RO plants. The present study suggested that UFs acted synergistically with periodic thermal disinfection for the remediation of RO plants.

Download full-text PDF

Source
http://dx.doi.org/10.5731/pdajpst.2017.008482DOI Listing

Publication Analysis

Top Keywords

thermal disinfection
24
periodic thermal
16
endotoxin increased
12
eu/ml plant
12
role heat-tolerant
8
ultrafilters ufs
8
ufs remediation
8
remediation reverse
8
reverse osmosis
8
osmosis plants
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!