Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: Although percutaneous transluminal angioplasty is an effective therapy against vascular access failure in hemodialysis patients, recurrent stenosis imposes enormous burden for hemodialysis patients. A nitinol scoring element-equipped helical balloon catheter (AngioSculpt) has been altered the landscape for treating several vascular diseases. It is not, however, fully elucidated whether AngioSculpt for advanced vascular access stenosis, difficult to expand by conventional balloons, successfully provides bailout angioplasty. Here, we report our cases whose intradialytic venous pressure significantly improved after percutaneous transluminal angioplasty without any serious adverse complications using AngioSculpt.
Patients And Methods: Among patients undergoing hemodialysis in Masuko Memorial Hospital, 16 cases with resistant and recurrent vascular access stenosis underwent AngioSculpt (diameter 6 mm, total length 4 cm) angioplasty. We simultaneously measured the average venous pressures during hemodialysis before and after percutaneous transluminal angioplasty.
Results: The average outflow vessel stenosis rate was 73.0 ± 11.3% before AngioSculpt intervention. Fully enlarged vessels were observed by expanding vessels at maximum pressure of 14 atm in all cases without any complications including vascular ruptures. Their intradialytic venous pressures decreased from 181.8 ± 39.2 mmHg to 150.5 ± 39.3 mmHg ( p < 0.0001).
Conclusion: AngioSculpt may provide a promising option for treating hemodialysis patients with severely advanced vascular access stenosis, who would otherwise need repeated vascular access surgeries and/or conventional percutaneous transluminal angioplasties.