Sedentary behavior (SB) has detrimental consequences and cannot be compensated for through moderate-to-vigorous physical activity (PA). In order to understand and mitigate SB, tools for measuring and monitoring SB are essential. While current direct-to-customer wearables focus on PA, the VitaBit validated in this study was developed to focus on SB. It was tested in a laboratory and in a free-living condition, comparing it to direct observation and to a current best-practice device, the ActiGraph, on a minute-by-minute basis. In the laboratory, the VitaBit yielded specificity and negative predictive rates (NPR) of above 91.2% for sitting and standing, while sensitivity and precision ranged from 74.6% to 85.7%. For walking, all performance values exceeded 97.3%. In the free-living condition, the device revealed performance of over 72.6% for sitting with the ActiGraph as criterion. While sensitivity and precision for standing and walking ranged from 48.2% to 68.7%, specificity and NPR exceeded 83.9%. According to the laboratory findings, high performance for sitting, standing, and walking makes the VitaBit eligible for SB monitoring. As the results are not transferrable to daily life activities, a direct observation study in a free-living setting is recommended.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5877308PMC
http://dx.doi.org/10.3390/s18030877DOI Listing

Publication Analysis

Top Keywords

sitting standing
12
free-living condition
8
direct observation
8
sensitivity precision
8
standing walking
8
validation vitabit
4
vitabit sit-stand
4
sit-stand tracker
4
tracker detecting
4
sitting
4

Similar Publications

The application of the Internet combined with extracurricular running exercise plays an important role in promoting the reform of school physical education teaching and the healthy development of students' physical fitness. 2379 students of Guilin Medical College used the Flash Campus APP for 30 weeks of running exercise during the school period, and the Wilcoxon test and t-test were used to statistically test the data of 50 m, standing long jump, lung capacity, seated forward bending, height, and body weight; men's pull-ups, 1,000 m; and women's sit-ups, 800 m pre- and post-tests. The Z/t values of men's 50 m, standing long jump, pull-ups, and lung capacity; women's 50 m running, standing long jump, sit-ups, lung capacity, and sitting prone flexion after extracurricular running exercise were - 3.

View Article and Find Full Text PDF

Introduction: Obesity in older adults is linked to various chronic conditions and decreased quality of life. Traditional physical activity guidelines often overlook the specific postures and movements that older adults engage in daily. This study aims to explore the compositional associations between posture-specific behaviours and obesity risk in younger (M = 67.

View Article and Find Full Text PDF

Maternal positions in childbirth - A cohort study of labouring women's movements and body positions the last 24 hours before birth.

Sex Reprod Healthc

December 2024

Department of Midwifery, University College of Northern Denmark, Selma Lagerløfsvej 2, 9220 Aalborg Ø, Denmark; Department of Clinical Medicine, Aarhus University, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark; Department of Occupational Health, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark; School of Nursing and Midwifery, Western Sydney University, Locked Bag 1797, Penrith, NSW 2751, Australia.

Introduction: Maternal position plays an essential role in achieving labour progress as it supports the physiological mechanisms of labour. Evidence supports that adopting upright positions may facilitate physiological childbirth.

Aim: To describe the use of various positionsamong nulliparous pregnant women in the last 24 h before birth and describe physical positions in relation to maternal and neonatal outcomes at time of birth.

View Article and Find Full Text PDF

Background/objectives: This study aims to investigate the daily variations in upper and lower body power performance in adolescent volleyball players.

Methods: The sample consisted of 50 young male volleyball players (14.12 ± 0.

View Article and Find Full Text PDF

: Instability is a major reason for revision after total hip arthroplasty (THA), and acetabular cup placement in the "traditional" safe zone does not protect against dislocations. Spinopelvic mobility may play a role in impingement and dislocation after THA. Personalized acetabular cup placement that incorporates spinopelvic mobility is currently lacking in the literature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!