Objective: It has been a widely accepted practice that a previous placed pacemaker, automatic implantable cardioverter defibrillators, or central line can be a contraindication to placing a hemodialysis catheter in the ipsilateral jugular vein. Fear of dislodging pacing wires, tunneling close to the battery site or causing venous obstruction has been a concern for surgeons and interventionalists alike. We suggest that this phobia may be unfounded.

Methods: A retrospective review was conducted of patients in whom hemodialysis catheters were placed over a period of 10 years. For each hemodialysis catheter that was placed, perioperative chest X-ray performed was used to evaluate for pre-existing pacemakers and central lines. The position and laterality of placement of the hemodialysis catheter along with presence of arteriovenous fistula with functional capacity for access were noted.

Results: A total of 600 hemodialysis catheters were placed in patients over the period of 10 years. The mean age of the patients was 73.6 ± 12 years with a median age of 76 years. We found 20 pacemakers or automatic implantable cardioverter defibrillators and 19 central lines on the same side of the neck as the hemodialysis catheter that was placed in the ipsilateral jugular vein. No patient exhibited malfunction or dislodgment of the central line, the pacemaker, or automatic implantable cardioverter defibrillator or evidence of upper extremity venous obstruction based upon signs symptoms or duplex exams.

Conclusion: Based on our experience, we suggest that placement of hemodialysis catheter in the internal jugular vein ipsilateral to the pre-existing catheter/leads is safe and spares the contralateral limb for arteriovenous fistula creation.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1129729818757964DOI Listing

Publication Analysis

Top Keywords

hemodialysis catheter
20
hemodialysis catheters
12
central lines
12
automatic implantable
12
implantable cardioverter
12
jugular vein
12
hemodialysis
8
pacemaker automatic
8
cardioverter defibrillators
8
defibrillators central
8

Similar Publications

Background: Globally, haemodialysis is the most frequent type of kidney replacement therapy and necessitates access to the bloodstream either through a native arteriovenous fistula, arteriovenous graft or central venous catheter. Vascular access complications are a major cause of morbidity and mortality in adults receiving haemodialysis, and effective vascular access self-management is required.

Objective: To examine the effectiveness of educational or behavioural interventions designed to improve self-management of long-term vascular access in adults receiving haemodialysis.

View Article and Find Full Text PDF

Background: Nursing sensitive indicators are a way of measuring aspects of patient care that are most affected by the actions of the nurse. Despite the existence of nursing sensitive indicators, these are largely not suitable to measure peritoneal dialysis nursing practice.

Objective: This project aimed to co-develop a set of peritoneal dialysis nursing-sensitive indicators.

View Article and Find Full Text PDF

Background: An effectively functioning arteriovenous fistula (AVF) is vital for end-stage renal disease patients. This study aims to evaluate the effects of Fogarty balloon catheter dilation on creating an effectively functioning AVF.

Methods: This retrospective cohort study was conducted at our clinic between 2020 and 2022.

View Article and Find Full Text PDF

Background: This study aimed to investigate the clinical outcomes of percutaneous transluminal angioplasty (PTA) in patients undergoing hemodialysis with different types of superior vena cava obstruction (SVCO) lesions.

Methods: This retrospective observational study recruited patients undergoing hemodialysis with SVCO and analyzed the clinical characteristics of SVCO. Patency rates were collected for patients treated with PTA and were assessed using the t-test, U-test, log-rank test and survival analyses such as the Kaplan-Meier method.

View Article and Find Full Text PDF

Background: External jugular vein (EJV) is used to insert tunneled dialysis catheter (TDC) in patients with no AVF and exhausted right internal jugular veins (IJV). There is scarce data on TDC insertion in EJV by nephrologists with fluoroscopy guidance.

Materials And Methods: This was a prospective observational study that included hemodialysis patients with exhausted right IJV access who underwent EJV TDC insertion, and excluded occluded ipsilateral brachiocephalic vein or superior vena cava, EJV < 5 mm diameter, or patients with existing EJV TDC.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!