AI Article Synopsis

  • The study aimed to validate the SenseWear Pro3 Armband (SWA) by comparing its step counts against a standard pedometer (DIGI) during treadmill walking and free-living conditions.
  • In the treadmill study, the SWA consistently underestimated steps at varying speeds, with the highest underestimation of 16.0%.
  • However, during free-living conditions, the SWA overestimated step counts by an average of 1028 steps per day, suggesting inconsistencies in its accuracy and indicating a need for improvements in step counting reliability.

Article Abstract

Background/objective: Advances in technology continue to provide numerous options for physical activity assessment. These advances necessitate evaluation of the validity of newly developed activity monitors being used in clinical and research settings. The purpose of this study was to validate the SenseWear Pro3 Armband (SWA) step counts during treadmill walking and free-living conditions.

Methods: Study 1 observed 39 individuals (17 males, 22 females) wearing an SWA and a Yamax Digiwalker SW-701 pedometer (DIGI) during treadmill walking, utilizing manually counted steps as the criterion. Study 2 compared free-living step count data from 35 participants (17 males, 18 females) wearing the SWA and DIGI (comparison) for 3 consecutive days.

Results: During Study 1, the SWA underestimated steps by 16.0%, 10.7%, 5.6%, 6.1%, and 6.5% at speeds of 54 m/min, 67 m/min, 80 m/min, 94 m/min, and 107 m/min, respectively, compared to manually counted steps. During Study 2, the intraclass correlation (ICC) coefficient of mean steps/d between the SWA and DIGI was strong (r = 0.98,  < 0.001). Unlike Study 1, the SWA overestimated step counts during the 3-day wear period by an average of 1028 steps/d (or +11.3%) compared to the DIGI. When analyzed individually, the SWA consistently overestimated step counts for each day ( < 0.05).

Conclusion: The SWA underestimates steps during treadmill walking and appears to overestimate steps during free-living compared to the DIGI pedometer. Caution is warranted when using the SWA to count steps. Modifications are needed to enhance step counting accuracy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5812852PMC
http://dx.doi.org/10.1016/j.jesf.2014.11.002DOI Listing

Publication Analysis

Top Keywords

step count
8
treadmill walking
8
males females
8
females wearing
8
wearing swa
8
manually counted
8
counted steps
8
swa digi
8
study
5
swa
5

Similar Publications

Investigation of growth and sporulation during larval rearing.

Heliyon

December 2024

Wageningen Food Safety Research, Akkermaalsbos 2, P.O. box 230, 3700 AE, Wageningen, the Netherlands.

Insects are increasingly used as an alternative protein source for feed and food production. One of the main biological hazards associated with edible insects is the bio-accumulation of foodborne pathogenic microorganisms. In this study, the interaction of larvae of the black soldier fly (BSFL, (L.

View Article and Find Full Text PDF

Purpose: Effective rehabilitation after orthopaedic surgery is critical. The early post-operative phase is increasingly managed in outpatient settings, necessitating objective measures such as step counts to monitor rehabilitation progress. However, it remains unclear if commercially available wearables or accelerometers using simple algorithms can accurately count steps in early post-operative conditions.

View Article and Find Full Text PDF

Introduction: Cardiovascular disease (CVD) is the leading cause of mortality worldwide, though it may be prevented by increasing physical activity (PA). When behaviour change techniques (BCTs) are bundled together, they increase PA, though which individual BCTs increase PA (and the behavioural mechanism of action (MoA) responsible for said increase) have not been studied. The aim of this study is to conduct a randomised factorial experiment to determine which of four BCTs significantly engage the proposed MoA-self-efficacy for PA-in adults at risk for CVD.

View Article and Find Full Text PDF

BACKGROUNDAlthough physical activity is an important outcome in patients with chronic respiratory disease, it has not been characterised in those with non-tuberculous mycobacterial pulmonary disease (NTM-PD). This study aimed to evaluate physical activity and its associated factors in patients with NTM-PD.METHODSThis prospective observational study measured daily step counts using an accelerometer to assess physical activity (steps per day).

View Article and Find Full Text PDF

Step Count: The Next Vital Sign.

J Gen Intern Med

January 2025

Department of Cardiology, The Texas Heart Institute, 6770 Bertner Ave, MC3-116, Houston, TX, 77030, USA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!