A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of apple juice authenticity using gas chromatography-mass spectrometry, volt-ampere and new conductometric methods. | LitMetric

Background: Organoleptic properties and positive health effect on consumers both justify the importance of determining apple juice authenticity with respect to retail and wholesale trade networks worldwide.

Results: Adulteration of apple juice through dilution with water, as well as with ascorbic acid, has been determined. It has been demonstrated that polarization curves of a platinum electrode in apple juice are useful for undeclared antioxidant determination, as a result of the movement of the polarization curve to the left, by 200 mV, when ascorbic acid was added. A difference between the equivalent electrical conductivity of suspended solids of undiluted and diluted (1:1) juices has been substantiated as a new quantitative criterion for determining adulteration through dilution. The criterion values range from 0.030 to 0.034 S m for juices of different apple varieties. Gas chromatography-mass spectrometry results have shown the presence of (E)-2-hexenal and n-hexanal in all juices tested obtained from different apple varieties.

Conclusion: A new conductometric method for the determination of diluted apple juices has been substantiated. It has been established that the volt-ampere method is useful for the investigation of undeclared ascorbic acid. © 2018 Society of Chemical Industry.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jsfa.9003DOI Listing

Publication Analysis

Top Keywords

apple juice
16
ascorbic acid
12
juice authenticity
8
gas chromatography-mass
8
chromatography-mass spectrometry
8
juices substantiated
8
apple
6
determination apple
4
juice
4
authenticity gas
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!