Purpose: Primary angle-closure glaucoma (PACG) is associated with increased intraocular pressure, optic nerve damage, and progressive vision loss, but the molecular mechanism that underpins retinal ganglion neuropathy in PACG remains poorly understood. To better understand the pathogenesis of human PACG, we performed the first comprehensive proteomic analysis of aqueous humor (AH) samples from PACG patients and matched control donors to study pathogenic alteration in AH composition in disease.
Methods: High-resolution, label-free, liquid chromatography-tandem mass spectrometry-based quantitative proteomic analyses were performed in AH samples collected from PACG patients and a matched control cohort of patients with cataracts.
Results: The AH proteome comprised of 1363 distinct proteins, of which more than 50% were differentially expressed in PACG (773 total; 501 up-regulated, 272 down-regulated). AH from PACG patients was enriched in atypical collagens and fibronectins, suggesting that the composition of the trabecular matrix is significantly altered in disease. Pathway and cluster analyses revealed that AH protein modulation in PACG is closely associated with biological processes including platelet degranulation, cellular import/export mechanisms, and control of protease activity. In addition, critical mediators of oxygen homeostasis and neuronal function in AH were significantly dysregulated in disease, strongly implicating oxidative stress responses in PACG-associated nerve damage.
Conclusions: Altered AH proteome in human PACG indicated oxidative stress in the neuronal damage that preceded vision loss. Identifying key mediators of PACG pathology will yield new prognostic biomarkers and novel targets for future therapeutic interventions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10792-018-0885-3 | DOI Listing |
Sci Rep
January 2025
Ophthalmic Pathology Laboratory, L V Prasad Eye Institute, Kallam Anji Reddy Campus, 500034, Hyderabad, India.
To examine ultrastructural changes in the trabecular meshwork (TM) in patients with primary and secondary glaucoma using scanning electron microscopy (SEM). This was a qualitative descriptive hospital-based study on the ultrastructure of the TM. Pure TM samples were collected after microincisional trabeculectomy from 26 patients with primary or secondary glaucoma and 10 control samples from eye bank donor corneas.
View Article and Find Full Text PDFCureus
November 2024
Department of Ophthalmology, Hiroshima University, Hiroshima, JPN.
Background Investigation of the safety and efficacy of phacoemulsification with trabecular microbypass Stent W implantation in patients with primary angle-closure glaucoma (PACG). Methods Between August and December of 2023, this prospective study evaluated PACG patients who underwent phacoemulsification with iStent inject W implantation. All patients were 18 years and older and were monitored for 6 months after surgery.
View Article and Find Full Text PDFQuant Imaging Med Surg
December 2024
Department of Ophthalmology & Visual Science, Eye, Ear, Nose, and Throat Hospital, Shanghai Medical College, Fudan University, Shanghai, China.
Background: Primary angle-closure glaucoma (PACG) is a leading cause of irreversible blindness worldwide. However, the features of the morphology of Schlemm's canal (SC) in PACG eyes after phacoemulsification with goniosynechialysis (phaco-GSL) surgery are still unknown. This study aimed to evaluate changes in the SC in Chinese patients with PACG after phaco-GSL using swept-source optical coherence tomography (SS-OCT).
View Article and Find Full Text PDFNeuroscience
January 2025
Department of Ophthalmology, Jiangxi Provincial People's Hospital, The First Affiliated Hospital of Nanchang Medical College, Nanchang, Jiangxi 330006, People's Republic of China. Electronic address:
Int Ophthalmol
December 2024
Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Dong Xia Road, Shantou, Guangdong Province, People's Republic of China.
Purpose: This study aims to evaluate the accuracy of intraocular lens (IOL) power calculation formulas-including Kane, Emmetropia Verifying Optical (EVO) 2.0, SRK/T, Hoffer Q, Haigis standard, Haigis optimized, Holladay 1, Olsen, Barrett Universal II-in primary angle-closure glaucoma (PACG) eyes undergoing cataract surgery combined with goniosynechialysis (GSL).
Methods: Preoperative biometric data were obtained using the OA-2000.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!