The increasing interest in assessing physical demands in team sports has led to the development of multiple sports related monitoring systems. Due to technical limitations, these systems primarily could be applied to outdoor sports, whereas an equivalent indoor locomotion analysis is not established yet. Technological development of inertial measurement units (IMU) broadens the possibilities for player monitoring and enables the quantification of locomotor movements in indoor environments. The aim of the current study was to validate an IMU measuring by determining average and peak human acceleration under indoor conditions in team sport specific movements. Data of a single wearable tracking device including an IMU (Optimeye S5, Catapult Sports, Melbourne, Australia) were compared to the results of a 3D motion analysis (MA) system (Vicon Motion Systems, Oxford, UK) during selected standardized movement simulations in an indoor laboratory ( = 56). A low-pass filtering method for gravity correction (LF) and two sensor fusion algorithms for orientation estimation [Complementary Filter (CF), Kalman-Filter (KF)] were implemented and compared with MA system data. Significant differences ( < 0.05) were found between LF and MA data but not between sensor fusion algorithms and MA. Higher precision and lower relative errors were found for CF (RMSE = 0.05; CV = 2.6%) and KF (RMSE = 0.15; CV = 3.8%) both compared to the LF method (RMSE = 1.14; CV = 47.6%) regarding the magnitude of the resulting vector and strongly emphasize the implementation of orientation estimation to accurately describe human acceleration. Comparing both sensor fusion algorithms, CF revealed slightly lower errors than KF and additionally provided valuable information about positive and negative acceleration values in all three movement planes with moderate to good validity (CV = 3.9 - 17.8%). Compared to x- and y-axis superior results were found for the z-axis. These findings demonstrate that IMU-based wearable tracking devices can successfully be applied for athlete monitoring in indoor team sports and provide potential to accurately quantify accelerations and decelerations in all three orthogonal axes with acceptable validity. An increase in accuracy taking magnetometers in account should be specifically pursued by future research.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5835232PMC
http://dx.doi.org/10.3389/fphys.2018.00141DOI Listing

Publication Analysis

Top Keywords

team sports
12
sensor fusion
12
fusion algorithms
12
player monitoring
8
monitoring indoor
8
indoor team
8
inertial measurement
8
measurement units
8
average peak
8
acceleration values
8

Similar Publications

The Impact of Physical Therapy Postprofessional Education Programs on Productivity in a Large Academic Medical Center.

J Phys Ther Educ

January 2025

John J. DeWitt is the associate director, education and professional development and associate clinical professor in the Rehab Services at The Ohio State University Wexner Medical Center, and School of Health & Rehabilitation Sciences, College of Medicine, The Ohio State University, 453 W 10th Ave, Rm 516, Columbus, OH 43210 Please address all correspondence to John J. DeWitt.

Introduction: Emerging evidence shows positive impact of postprofessional physical therapy education (residency and fellowship) specific to participants; however, outcomes on organizational impact are largely unknown. The purpose of this project was to describe the impact residency and fellowship training has on financial metrics. A secondary purpose of this case study was to describe trends associated with higher productivity.

View Article and Find Full Text PDF

Background: Delirium and cognitive impairment are common in hip fracture populations and are associated with significant adverse patient outcomes. National hip fracture registries facilitate improvements in patient outcomes and care quality, such as reduced mortality and the development of specialist multidisciplinary services. However, there is substantial variation in the data collected and reported in relation to delirium and cognition, which impedes international comparison and may reduce quality of care.

View Article and Find Full Text PDF

Objective: Guardian Caps (GCs) have been widely implemented at all levels of American football participation based on laboratory evidence that they may reduce head impact forces. The purpose of this study was to determine if GC use during practice was associated with a lower risk of sport-related concussion (SRC) during practices and games among high school football players.

Methods: Data were collected on 2610 athletes from 41 Wisconsin schools that self-selected into GC or Non-GC cohorts.

View Article and Find Full Text PDF

Context: There is a minimal number of studies of under-21-year-old national football teams, and the literature is injury centric. Particularly, current knowledge is deficient regarding noninjurious medical conditions, such as illnesses and diseases.

Design: The objectives of this study were to analyze the descriptive characteristics of injuries and illnesses or diseases encountered in an under-21 football team during 2 European championship qualification tournaments.

View Article and Find Full Text PDF

Despite trust being associated with a range of favorable outcomes across high-performing team contexts (e.g., enhanced satisfaction, performance), efforts to investigate the meaning of trust in sport remain limited.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!