The ultrafine particle measurements in the Augsburger Umweltstudie, a panel study conducted in Augsburg, Germany, exhibit measurement error from various sources. Measurements of mobile devices show classical possibly individual-specific measurement error; Berkson-type error, which may also vary individually, occurs, if measurements of fixed monitoring stations are used. The combination of fixed site and individual exposure measurements results in a mixture of the two error types. We extended existing bias analysis approaches to linear mixed models with a complex error structure including individual-specific error components, autocorrelated errors, and a mixture of classical and Berkson error. Theoretical considerations and simulation results show, that autocorrelation may severely change the attenuation of the effect estimations. Furthermore, unbalanced designs and the inclusion of confounding variables influence the degree of attenuation. Bias correction with the method of moments using data with mixture measurement error partially yielded better results compared to the usage of incomplete data with classical error. Confidence intervals (CIs) based on the delta method achieved better coverage probabilities than those based on Bootstrap samples. Moreover, we present the application of these new methods to heart rate measurements within the Augsburger Umweltstudie: the corrected effect estimates were slightly higher than their naive equivalents. The substantial measurement error of ultrafine particle measurements has little impact on the results. The developed methodology is generally applicable to longitudinal data with measurement error.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/bimj.201600188 | DOI Listing |
Clin Ophthalmol
December 2024
Department of Computer Science and Biomedical Informatics, University of Thessaly, Lamia, Greece.
Purpose: To identify the minimally required number of distances of visual acuity (VA) measurements for the reliable estimation of the visual acuity curve (VAC) and area of the curve (AoC) in presbyopia correction.
Patients And Methods: The study was divided into a validation and a clinical phase with a total recruitment of 120 participants (120 eyes) who underwent uncomplicated pseudophakic presbyopia surgery with bilateral premium intraocular lenses (IOL) implantation. This study was conducted in the Department of Ophthalmology, University Hospital of Alexandroupolis, Alexandroupolis, Greece.
Clin Neuropsychol
January 2025
Department of Neurology, Emory University School of Medicine, Emory University, Atlanta, GA, USA.
To introduce ABBA Letter Alternation (ABBA) as a computerized measure of response inhibition/response alternation developed for telehealth following restrictions of in-person testing due to COVID-19. ABBA consists of two PowerPoint-administered trials: Letter Reading of 25 capital As or Bs individually presented, and Letter Alternation with instructions to say the opposite letter to what is presented. We obtained initial normative ABBA performance from 899 healthy research volunteers participating in the Emory Healthy Brain Study (EHBS) with Montreal Cognitive Assessment (MoCA) scores 24/30 and higher.
View Article and Find Full Text PDFJMIR Mhealth Uhealth
January 2025
ULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.
Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non-laboratory-controlled conditions with actual specific and various physical activity movements.
Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities.
CNS Spectr
January 2025
Department of Psychiatry, University of Toronto, Toronto, ON, Canada.
Background: Improving functioning in adults with major depressive disorder (MDD) and bipolar disorder (BD) is a priority therapeutic objective.
Methods: This retrospective post hoc secondary analysis evaluated 108 patients with MDD or BD receiving the antidepressants vortioxetine, ketamine, or infliximab. The analysis aimed to determine if changes in objective or subjective cognitive function mediated the relationship between depression symptom severity and workplace outcomes.
J Am Med Inform Assoc
January 2025
Coordinating Center, Observational Health Data Science and Informatics, New York City, NY 10032, United States.
Objective: Propose a framework to empirically evaluate and report validity of findings from observational studies using pre-specified objective diagnostics, increasing trust in real-world evidence (RWE).
Materials And Methods: The framework employs objective diagnostic measures to assess the appropriateness of study designs, analytic assumptions, and threats to validity in generating reliable evidence addressing causal questions. Diagnostic evaluations should be interpreted before the unblinding of study results or, alternatively, only unblind results from analyses that pass pre-specified thresholds.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!