4πβ-γ coincidence method is a powerful and widely used method to determine the absolute activity concentration of radioactive solutions. A new automated liquid scintillator based coincidence system has been designed, developed, tested and established as absolute standard for radioactivity measurements. The automation is achieved using PLC (programmable logic controller) and SCADA (supervisory control and data acquisition). Radioactive solution of Co was standardized to compare the performance of the automated system with proportional counter based absolute standard maintained in the laboratory. The activity concentrations determined using these two systems were in very good agreement; the new automated system can be used for absolute measurement of activity concentration of radioactive solutions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2018.02.030DOI Listing

Publication Analysis

Top Keywords

absolute standard
12
coincidence system
8
system absolute
8
standard radioactivity
8
radioactivity measurements
8
activity concentration
8
concentration radioactive
8
radioactive solutions
8
automated system
8
absolute
5

Similar Publications

Maternal cell-free DNA in early pregnancy for preeclampsia screening: a systematic review.

Arch Gynecol Obstet

January 2025

Faculty of Medicine and Health Sciences, Tel Aviv University, Tel Aviv, Israel.

Purpose: To quantify the separation between maternal blood cell-free (cf)DNA markers in preeclampsia and unaffected pregnancies and compare with existing markers. This approach has not been used in previous studies.

Methods: Comprehensive systematic literature search of PubMed to identify studies measuring total cfDNA, fetal cf(f)DNA or the fetal fraction (FF) in pregnant women.

View Article and Find Full Text PDF

With the emergence of numerous classifications, surgical treatment for adolescent idiopathic scoliosis (AIS) can be guided more effectively. However, surgical decision-making and optimal strategies still lack standardization and personalized customization. Our study aims to devise proper deep learning (DL) models that incorporate key factors influencing surgical outcomes on the coronal plane in AIS patients to facilitate surgical decision-making and predict surgical results for AIS patients.

View Article and Find Full Text PDF

To retrospectively develop and validate an interpretable deep learning model and nomogram utilizing endoscopic ultrasound (EUS) images to predict pancreatic neuroendocrine tumors (PNETs). Following confirmation via pathological examination, a retrospective analysis was performed on a cohort of 266 patients, comprising 115 individuals diagnosed with PNETs and 151 with pancreatic cancer. These patients were randomly assigned to the training or test group in a 7:3 ratio.

View Article and Find Full Text PDF

Body fat percentage (BF%) is routinely measured in athletes to monitor training and dietary interventions. Dual energy x-ray absorptiometry (DXA) is widely considered the gold standard body composition measurement technique, but DXA BF% values measure consistently higher than other techniques. Therefore, the main purpose of this study is to determine the lowest DXA-estimated whole-body fat mass in free-living athletes with unrestricted access to food.

View Article and Find Full Text PDF

The current study investigated the geometry, design and solid angle impacts on full energy peak efficiency (FEPE) of NaI(Tl) detectors for a line source. A line source is fabricated using 99mTc solution filled in a borosilicate glass tube of inner diameter 3 mm, tube wall thickness 2.5 mm and length 12.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!