Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Continuous positive airway pressure (CPAP) is the first-choice treatment for obstructive sleep-disordered breathing. Automatic bilevel ventilation can be used to treat obstructive sleep-disordered breathing when CPAP is ineffective, but clinical experience is still limited. To assess the outcome of titration with CPAP and automatic bilevel ventilation, the charts of 356 outpatients (obstructive sleep apnea, n = 242; chronic obstructive pulmonary disease + obstructive sleep apnea overlap, n = 80; obesity hypoventilation syndrome [OHS], n = 34; 103 females) treated for obstructive sleep-disordered breathing from January 2014 to April 2017 were reviewed. Positive airway pressure titration was considered successful in the case of sleep-disordered breathing resolution (apnea-hypopnea index <10/hr) with cumulative time at SaO < 90% (CT90%) <10% and/or improved daytime arterial blood gases at the end of titration. CPAP was effective in 268 patients (75.0%). CPAP treatment failure (n = 88) occurred in 13.6% of obstructive sleep apnea, 32.5% of overlap, and 85.3% of OHS patients. Compared with successful CPAP cases, patients undergoing the automatic bilevel ventilation trial showed higher body mass index (39.3 ± 10.5 kg/m versus 34.8 ± 6.9 kg/m , p < 0.0001), worse mean nocturnal SaO (89.2 ± 4.0% versus 91.3 ± 4.0%, p < 0.003) and CT90% (40.6 ± 28.6% versus 24.0 ± 23.3%), but similar age (62.8 ± 11.9 years versus 60.5 ± 12.0 years, p = 0.11), apnea-hypopnea index (39.4 ± 23.2/hr versus 41.0 ± 21.2/hr, p = 0.55) and oxygen desaturation index (37.8 ± 23.5/hr versus 39.2 ± 21.1/hr, p = 0.61) at diagnosis. Automatic bilevel ventilation was successful in 79.5% of CPAP treatment failures (n = 70). Automatic bilevel ventilation failure was independently associated with baseline body mass index >40 kg/m (odds ratio 6.16, confidence interval 1.50-25.17, p = 0.011) and CT90% >42% (odds ratio 5.87, confidence interval 1.39-24.83, p = 0.016). During follow-up, automatic bilevel ventilation treatment failed in seven patients (10%), and compliance was similar in CPAP (4.5 ± 2.2 hr) and automatic bilevel ventilation (5.2 ± 2.3 hr, p = 0.09) groups. Automatic bilevel ventilation was useful to treat sleep-disordered breathing, but failed in patients with severe OHS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jsr.12680 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!