A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A comparison of gait one year post operation in an RCT of robotic UKA versus traditional Oxford UKA. | LitMetric

Robot-assisted unicompartmental knee surgery has been shown to improve the accuracy of implant alignment. However, little research has been conducted to ascertain if this results in a measureable improvement in knee function post operatively and a more normal gait. The kinematics of 70 OA knees were assessed using motion analysis in an RCT (31 receiving robotic-assisted surgery, and 39 receiving traditional manual surgery) and compared to healthy knees. Statistically significant kinematic differences were seen between the two surgical groups from foot-strike to mid-stance. The robotic-assisted group achieved a higher knee excursion (18.0°, SD 4.9°) compared to the manual group (15.7°, SD 4.1°). There were no significant difference between the healthy group and the robotic assisted group, however there was a significant difference between the healthy group and the manual group (p < 0.001). Hence robotically-assisted knee replacement with Mako Restoris Implants appears to lead not only to better implant alignment but also some kinematic benefits to the user during gait.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gaitpost.2018.02.029DOI Listing

Publication Analysis

Top Keywords

manual group
8
difference healthy
8
healthy group
8
group
6
comparison gait
4
gait year
4
year post
4
post operation
4
operation rct
4
rct robotic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!