A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The predictive value of the CHA2DS2-VASc score in patients with mechanical mitral valve thrombosis. | LitMetric

Prosthetic valve thrombosis (PVT) is a potentially life-threatening complication associated with high morbidity and mortality. The CHA2DS2-VASc is a clinical score used to determine thromboembolism risk in non-valvular atrial fibrillation patients. Therefore; in this study, we aimed to determine predictive value of the CHA2DS2-VASc score for development of PVT in patients with mechanical prosthetic valve. This was a retrospective study included 417 consecutive patients with mechanic prosthetic valve in whom transesophageal echocardiography (TEE) was performed due to different clinical indications from January 2004 to June 2016. After evaluation according to exclusion criteria, 267 patients with mechanic prosthetic valve were enrolled in the study. The definitive diagnosis of the PVT was made as proposed by TEE finding. The study population was divided into two groups; PVT patients (154 patients) and control group (113 patients) with functional prosthetic valve. The CHA2DS2-VASc score was calculated for each patient from the hospital electronic database. The mechanical mitral valve thrombosis predictive value of variables including CHA2DS2-VASc score was tested in our study. The mean CHA2DS2-VASc score was significantly higher in PVT patients compared to control patients (2.51 ± 1.54 vs. 1.13 ± 1.21, p < 0.01). Both on univariate and multivariate analysis demonstrated that the CHA2DS2-VASc score is independently associated with PVT (p < 0.001 and p < 0.001, respectively). The patients whose CHA2DS2-VASc score ≥ 1-3 had 6.20 times higher risk for thrombus formation, and patients whose CHA2DS2-VASc score ≥ 4 had 16.6 times higher risk for thrombus formation compared to patients with CHA2DS2-VASc score = 0 (p < 0.001 and p < 0.001, respectively). The CHA2DS2-VASc score may be a significant independent predictor of PVT in patients with prosthetic valve and the CHA2DS2-VASc score ≥ 2.5 or more was associated with increased PVT in patients with prosthetic valve. Thus; it may be an applicable risk scoring system to assess the risk of development of PVT in patients with prosthetic valve.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11239-018-1640-3DOI Listing

Publication Analysis

Top Keywords

cha2ds2-vasc score
20
prosthetic valve
20
valve thrombosis
12
pvt patients
12
patients
10
predictive cha2ds2-vasc
8
patients mechanical
8
mechanical mitral
8
mitral valve
8
patients mechanic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!