Surgical fixation of midshaft clavicle fractures: A systematic review of biomechanical studies.

Injury

Department of Surgery, Diakonessenhuis Utrecht/Zeist/Doorn, Bosboomstraat 1, 3582 KE, Utrecht, The Netherlands; Department of Orthopaedic Surgery/Centre for Orthopaedic Research Alkmaar (CORAL), Medical Centre Alkmaar, Wilhelminalaan 12, 1815 JD, Alkmaar, The Netherlands.

Published: April 2018

Purpose: Surgical treatment of displaced midshaft clavicle fractures requires a decision between plate fixation and intramedullary (IM) fixation. Numerous studies report on the biomechanical properties of various repair constructs. The goal of this systematic review was to provide an overview of studies describing the biomechanical properties of the most commonly used surgical fixations of midshaft clavicle fractures. Additionally, we aimed to translate these biomechanical results into clinically relevant conclusions.

Methods: A computer-aided search of the EMBASE and PudMed/MEDLINE databases was conducted. Studies included for review compared biomechanical properties of plate fixation with IM fixation and superiorly positioned plates with anteroinferiorly positioned plates for midshaft clavicle fractures.

Results: Fifteen studies were eligible for inclusion. Plate fixation seemed to form a more robust construct than IM fixation in terms of stiffness and failure loading. The remaining clavicle was stronger after removal of the IM device than after removal of the plate. Superior plating of transverse fractures generally seemed to provide greater stiffness and strength during bending loads than anteroinferior plating did. The absence of cortical alignment in wedge and comminuted fractures directly influenced the fixation stability for both IM fixation and plate fixation, regardless of location.

Conclusion: Each type of fracture fixation has biomechanical advantages and disadvantages. However, exact thresholds of stiffness for inducing healing and failure strength to withstand refractures are unknown. The clinical relevance of the biomechanical studies may be arguable. Since none of the studies investigate the effect of tissue adaptation over time they should be interpreted with caution.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2018.02.017DOI Listing

Publication Analysis

Top Keywords

midshaft clavicle
16
plate fixation
16
clavicle fractures
12
biomechanical properties
12
fixation
10
systematic review
8
biomechanical studies
8
positioned plates
8
biomechanical
7
studies
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!