A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ratiometric fluorescence sensing of mercuric ion based on dye-doped lanthanide coordination polymer particles. | LitMetric

Ratiometric fluorescence sensing of mercuric ion based on dye-doped lanthanide coordination polymer particles.

Anal Chim Acta

College of Chemistry and Molecular Engineering, Zhengzhou University, Zhengzhou, 450001, PR China. Electronic address:

Published: July 2018

This work focused on the development of a novel ratiometric fluorescence sensor for detection of Hg by using dye-doped lanthanide infinite coordination polymer (Ln-ICP) particles. The dye-doped Ln-ICP used herein was prepared by self-assemble of adenosine monophosphate (AMP) with Ce and Tb (Ce/Tb-AMP) through self-adaptive chemistry, in which the fluorescent dye coumarin was encapsulated during the assembly process as a guest molecule. Under 310 nm irradiation, the obtained coumarin@Ce/Tb-AMP itself emitted characteristic green luminescence of Tb, accompanied with a weak fluorescence at 445 nm originated from coumarin encapsulated in the Ce/Tb-AMP networks. The fluorescence emission of coumarin became strong when it was released to the solution. In the presence of Hg, the coumarin@Ce/Tb-AMP was destroyed due to the specific coordination interaction between AMP and Hg, which leaded to the release of coumarin to the solution meanwhile. Consequently, the fluorescence of Ce/Tb-AMP was quenched, while that of coumarin enhanced. On the basis of this strategy, we developed a novel ratiometric fluorescent sensor for the detection of Hg by measuring the ratio of fluorescent intensity of the coumarin@Ce/Tb-AMP suspension, which showed a wide linear range from 0.08 to 1000 nM and detection limit of 0.03 nM with high selectivity and sensitivity. Furthermore, the constructed ratiometric fluorescent sensor was successfully applied in detecting Hg in drinking water and human blood serum (HBS) with satisfactory results.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2018.01.065DOI Listing

Publication Analysis

Top Keywords

ratiometric fluorescence
8
dye-doped lanthanide
8
coordination polymer
8
novel ratiometric
8
sensor detection
8
coumarin encapsulated
8
ratiometric fluorescent
8
fluorescent sensor
8
coumarin
5
ratiometric
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!