A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Wearable Inertial Sensors for Fall Risk Assessment and Prediction in Older Adults: A Systematic Review and Meta-Analysis. | LitMetric

Wearable inertial sensors have been widely investigated for fall risk assessment and prediction in older adults. However, heterogeneity in published studies in terms of sensor location, task assessed and features extracted is high, making challenging evidence-based design of new studies and/or real-life applications. We conducted a systematic review and meta-analysis to appraise the best available evidence in the field. Namely, we applied established statistical methods for the analysis of categorical data to identify optimal combinations of sensor locations, tasks, and feature categories. We also conducted a meta-analysis on sensor-based features to identify a set of significant features and their pivot values. The results demonstrated that with a walking test, the most effective feature to assess the risk of falling was the velocity with the sensor placed on the shins. Conversely, during quite standing, linear acceleration measured at the lower back was the most effective combination of feature-placement. Similarly, during the sit-to-stand and/or the stand-to-sit tests, linear acceleration measured at the lower back seems to be the most effective feature-placement combination. The meta-analysis demonstrated that four features resulted significantly higher in fallers: the root-mean-square acceleration in the mediolateral direction during quiet standing with eyes closed [Mean Difference (MD): 0.01 g; 95% Confidence Interval (CI95%): 0.006 to 0.014]; the number of steps (MD: 1.638 steps; CI95%: 0.384 to 2.892) and total time (MD: 2.274 seconds; CI95%: 0.531 to 4.017) to complete the timed up and go test; and the step time (MD: 0.053; CI95%: 0.012 to 0.095; p = 0.01) during walking.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TNSRE.2017.2771383DOI Listing

Publication Analysis

Top Keywords

wearable inertial
8
inertial sensors
8
fall risk
8
risk assessment
8
assessment prediction
8
prediction older
8
older adults
8
systematic review
8
review meta-analysis
8
linear acceleration
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!