A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection of multipoint pulse waves and dynamic 3D pulse shape of the radial artery based on binocular vision theory. | LitMetric

Background And Objective: Pulse signals contain a wealth of human physiological and pathological information. How to get full pulse information is especially challenging, and most of the traditional pulse sensors can only get the pulse wave of a single point. This study is aimed at developing a binocular pulse detection system and method to obtain multipoint pulse waves and dynamic three-dimensional pulse shape of the radial artery.

Methods: The proposed pulse detection approach is image-based and implemented by two steps. First, a new binocular pulse detection system is developed based on the principle of pulse feeling used in traditional Chinese medicine. Second, pulse detection is achieved based on theories and methods of binocular vision and digital image processing. In detail, the sequences of pulse images collected by the designed system as experimental data are sequentially processed by median filtering, block binarization and inversion, area filtering, centroids extraction of connected regions, to extract the pattern centroids as feature points. Then stereo matching is realized by a proposed algorithm based on Gong-shape scan detection. After multipoint spatial coordinate calculation, dynamic three-dimensional reconstruction of the thin film shape is completed by linear interpolation. And then the three-dimensional pulse shape is achieved by finding an appropriate reference time. Meanwhile, extraction of multipoint pulse waves of the radial artery is accomplished by using a suitable reference origin. The proposed method is analyzed from three aspects, which are pulse amplitude, pulse rate and pulse shape, and compared with other detection methods.

Results: Analysis of the results shows that the values of pulse amplitude and pulse rate are consistent with the characteristics of pulse wave of the radial artery, and pulse shape can correctly present the shape of pulse in space and its change trend in time. The comparison results with the other two previously proposed methods further verify the correctness of the presented method.

Conclusions: The designed binocular pulse detection system and proposed algorithm can effectively detect pulse information. This tactile visualization-based pulse detection method has important scientific significance and broad application prospects and will promote further development of objective pulse diagnosis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2017.11.025DOI Listing

Publication Analysis

Top Keywords

pulse
28
pulse detection
24
pulse shape
20
multipoint pulse
12
pulse waves
12
radial artery
12
binocular pulse
12
detection system
12
detection
9
detection multipoint
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!