Background: Selection and verification of blood collection tubes is an important preanalytical issue in clinical laboratories. Today, gel tubes are commonly used with many advantages, although they are known to cause interference in immunoassay methods. In this study, we aimed to compare SSTs of two different suppliers (Ayset clot activator & Gel and Becton Dickinson (BD) Vacutainer SST II advance) with reference tubes and evaluate the effect of storage time in terms of commonly used endocrine tests such as thyroid-stimulating hormone (TSH), free thyroxine (fT4), and free triiodothyronine (fT3).

Methods: Fifty-five volunteers were included in the study. Samples were taken into three different tubes and analyzed for serum TSH, fT4, and fT3 on Architect ci8200 Immunoassay System. Clinical decision levels were estimated using total allowable error (TEa).

Results: No difference was found between tubes in terms of TSH, fT3, and fT4 levels. From a statistical standpoint, TSH and fT4 levels were no longer stable during 24, 48, and 72 hours storage time periods. However, their variations were not clinically significant.

Conclusion: Ayset clot activator & Gel tubes and BD Vacutainer SST II advance tubes have comparable results with glass tube in terms of TSH, fT3, and fT4 levels on Architect ci8200 Immunoassay Systems. From a clinical standpoint, serum TSH, fT4, and fT3 concentrations may be considered as stable when storing these tubes over 72 hours.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6816829PMC
http://dx.doi.org/10.1002/jcla.22427DOI Listing

Publication Analysis

Top Keywords

tsh ft4
12
ft4 levels
12
tubes
9
gel tubes
8
ayset clot
8
clot activator
8
activator gel
8
vacutainer sst
8
sst advance
8
storage time
8

Similar Publications

Since the early discovery of QRFP43, intensive research has been primarily focused on its role in the modulation of food intake. As is widely recognised, the regulation of the body's energy status is a highly complex process involving numerous systems, hormones and neurotransmitters. Among the most important regulators of energy status, alongside the satiety and hunger centre located in the hypothalamus, is the HPT axis, which directly and indirectly affects the regulation of metabolism in all cells of the body.

View Article and Find Full Text PDF

Gaucher disease (GD), the most common ultra-rare metabolic disorder, results from lipid accumulation. Systemic inflammation, cellular stress, and metabolic dysfunction may influence endocrine function, including the thyroid. This study evaluated thyroid function and morphology in 60 GD patients, alongside carbohydrate and lipid metabolism.

View Article and Find Full Text PDF

Thyroid function is closely linked to circadian rhythms, but the relationship between the frequency of night eating and thyroid function remains unclear. Our study aimed to investigate the association between night eating frequency and its impact on thyroid function and sensitivity. This study included 6093 participants from the U.

View Article and Find Full Text PDF

Background: The superior thyroid artery (STA) as a recipient vessel in free flap reconstruction may theoretically impact thyroid function. This study aimed to assess whether the use of the STA has an adverse effect on thyroid function.

Methods: Retrospective review of 101 head and neck reconstructive cases.

View Article and Find Full Text PDF

Background: Laboratory stewardship programs are increasingly adopted to enhance test utilization and improve patient care. Despite their potential, implementation within complex healthcare systems remains challenging. Benchmarking metrics helps institutions compare their performance against peers or best practices.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!