Background: The potential protective effects of remote ischemic preconditioning (RIPC) on contrast-induced nephropathy (CIN) after percutaneous coronary intervention (PCI) remain to be defined.

Methods And Results: A double blind, randomized, placebo controlled multicenter study was performed. Patients younger than 85years old, with a renal clearance of 30-60ml/min/1.73m, who were candidates for PCI for all clinical indications except for primary PCI, were allocated 1:1 to RIPC or to standard therapy. The primary endpoint was incidence of CIN. The secondary endpoint was incidence of peri-procedural myocardial infarction (PMI). From February 2013 to April 2014, 3108 patients who were scheduled for coronary angiography were screened for the study. 442 fulfilled the inclusion criteria and 223 received PCI. These patients were randomized to sham RIPC (n=107) or treatment group (n=116). The only pre-specified subgroup of diabetic patients included 85 (38%) cases. RIPC significantly reduced CIN incidence in the overall population (12.1% vs. 26.1%, p=0.01, with a NNT=9) and in non-diabetic patients (9.2% vs. 25.0%, p=0.02), but showed no benefit in diabetics (16.7% vs. 28.2%, p=0.21). A trend for lower PMI was seen in the intervention arm (creatine kinase - muscle brain >5 URL; 8.4% vs. 16.4%, p=0.07; troponin T >5 URL; 27% vs. 38%, p=0.21).

Conclusions: Remote ischemic preconditioning significantly reduces the incidence of acute kidney injury in non-diabetic patients undergoing PCI. Larger sample size is presumably needed to assess the effect of RIPC for patients with diabetes mellitus. Clinical Trial number:NCT02195726https://www.clinicaltrial.gov/.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2017.12.033DOI Listing

Publication Analysis

Top Keywords

remote ischemic
12
ischemic preconditioning
12
endpoint incidence
8
non-diabetic patients
8
patients
7
ripc
5
pci
5
european chinese
4
chinese cardiac
4
cardiac renal
4

Similar Publications

MOTS-c mimics remote ischemic preconditioning in protecting against lung ischemia-reperfusion injury by alleviating endothelial barrier dysfunction.

Free Radic Biol Med

January 2025

Department of Anesthesiology, The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University, Wuxi, Jiangsu, China,214023. Electronic address:

Remote ischemic preconditioning (RIPC) induces the expression of unidentified protective cytokines that mitigate lung ischemia-reperfusion injury (LIRI). This study hypothesizes that MOTS-c, a mitokine with potent protective effects against mitochondrial damage, contributes to RIPC-mediated protection by alleviating endothelial barrier dysfunction. In human lung transplantation patients, serum levels of MOTS-c significantly decreased following IR injury but were markedly increased when RIPC was performed prior to transplantation.

View Article and Find Full Text PDF

Objective: After a recent small subcortical infarct (RSSI), some patients develop perilesional or remote hyperintensities ('caps/tracks') to the index infarct on T2/FLAIR MRI. However, their clinical relevance remains unclear. We investigated the clinicoradiological correlates of 'caps/tracks', and their impact on long-term outcomes following RSSI.

View Article and Find Full Text PDF

Remote Ischemic Preconditioning (RIPC) is a therapy characterized by repeated bouts of limb ischemia and reperfusion. RIPC protects against ischemia-reperfusion injury (IRI), and preclinical studies suggest that this is mediated through release of endogenous opioids. We aimed to interrogate the role of endogenous opioids in RIPC-signaling in humans, using an arm model of IRI.

View Article and Find Full Text PDF

Background: The risk-benefit ratio of the Absorb bioresorbable vascular scaffold (BVS) may vary before and after 3 years, the time point of complete bioresorption of the poly-L-lactic acid scaffold.

Objectives: The aim of this study was to determine the time-varying outcomes of the Absorb BVS compared with cobalt-chromium everolimus-eluting stents (EES) from a large individual-patient-data pooled analysis of randomized trials.

Methods: The individual patient data from 5 trials that randomized 5,988 patients undergoing percutaneous coronary intervention to the Absorb BVS vs EES with 5-year follow-up were pooled.

View Article and Find Full Text PDF