A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reduction in exposure of interventional cardiologists to ionising radiation over a 10-year period. | LitMetric

Exposure of operators to ionising radiation in interventional cardiology has likely diminished, but data confirming the magnitude of the reduction are lacking. The aim of this study was to compare the dose of radiation received by interventional cardiology operators at 11 years interval (2006 vs 2017). The study population comprised all interventional coronary procedures performed by a single operator in one catheterization laboratory (cathlab) of a large university hospital in north-eastern France. Exposure was compared between two periods, namely period 1 (from October 2005 to March 2006) and period 2 (from March 2017 to June 2017). The primary endpoint was the dose of radiation received by the operator, measured using an electronic dosimeter placed on the operator's left arm. In 2017, the dose of radiation received by the operators was, on average, 95% lower than the dose received in 2006 (p < 0.0001), even though the average fluoroscopy time increased by 73% over the same period (p < 0.0001). By multivariable analysis including body mass index, fluoroscopy time and performance of at least one (1) coronary angioplasty, the reduction in the operator's exposure to radiation remained significant. The dose of radiation received by interventional cardiology operators has decreased by 95% over the last ten years.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2018.02.026DOI Listing

Publication Analysis

Top Keywords

dose radiation
12
radiation received
12
ionising radiation
8
interventional cardiology
8
radiation
5
reduction exposure
4
interventional
4
exposure interventional
4
interventional cardiologists
4
cardiologists ionising
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!