A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Efficacy and safety of a second-generation biodegradable polymer sirolimus-eluting stent: One-year results of the CREDIT 2 trial. | LitMetric

Aims: We performed a multicenter, randomized controlled trial to determine the noninferiority of a novel biodegradable polymer drug-eluting stent (BP-DES), the EXCEL 2 stent, to the first-generation BP-DES, the EXCEL stent.

Methods And Results: Patients (n = 419) scheduled to undergo percutaneous coronary intervention (PCI) were randomized to receive either the EXCEL 2 stent (n = 208) or the EXCEL stent (n = 211) from 15 Chinese centers. At 9 months, primary endpoint in-stent late loss (LL) difference was -0.03 mm (95% confidence interval: -0.09 mm to 0.04 mm) between the EXCEL 2 group (0.14 ± 0.26 mm) and the EXCEL group (0.16 ± 0.36 mm), demonstrating the noninferiority of EXCEL 2 to EXCEL in terms of in-stent LL (P for noninferiority < .0001). Besides, target lesion failure (TLF) was statistically lower in EXCEL 2 group compared with EXCEL through 1 year (HR [95%CI] = 0.45 [0.20,0.98], P = .04). Definite/probable ST was observed in 0.0% vs 1.9% (P = .12) of EXCEL 2 vs EXCEL-treated subjects.

Conclusions: The second-generation BP-DES (EXCEL 2) was noninferior to the first-generation BP-DES (EXCEL) for the primary endpoint of in-stent LL at 9 months. Clinical Trial Registration-URL: http://www.clinicaltrials.gov. Unique identifier: NCT02057978.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1755-5922.12327DOI Listing

Publication Analysis

Top Keywords

excel stent
12
biodegradable polymer
8
excel
8
bp-des excel
8
excel group
8
stent
5
efficacy safety
4
safety second-generation
4
second-generation biodegradable
4
polymer sirolimus-eluting
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!