A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dosimetric assessment of an air-filled balloon applicator in HDR vaginal cuff brachytherapy using the Monte Carlo method. | LitMetric

Purpose: As an alternative to cylindrical applicators, air-inflated balloon applicators have been introduced into high-dose-rate (HDR) vaginal cuff brachytherapy to achieve sufficient dose to the vagina mucosa as well as to spare organs at risk, mainly the rectum and bladder. Commercial treatment planning systems which employ formulae in the AAPM Task Group No. 43 (TG 43) report do not take into account tissue inhomogeneity. Consequently, the low-density air in a balloon applicator induces different doses delivered to the mucosa from planned by these planning systems. In this study, we investigated the dosimetric effects of the air in a balloon applicator using the Monte Carlo (MC) method.

Methods: The thirteen-catheter Capri™ applicator by Varian™ for vaginal cuff brachytherapy was modeled together with the Ir-192 radioactive source for the microSelectron™ Digital (HDR-V3) afterloader by Elekta™ using the MCNP MC code. The validity of charged particle equilibrium (CPE) with an air balloon present was evaluated by comparing the kerma and the absorbed dose at various distances from the applicator surface. By comparing MC results with and without air cavity present, dosimetric effects of the air cavity were studied. Clinical patient cases with optimized multiple Ir-192 source dwell positions were also explored. Four treatment plans by the Oncentra Brachy™ treatment planning system were re-calculated with MCNP.

Results: CPE fails in the vicinity of the air-water interface. One millimeter beyond the air-water boundary the kerma and the absorbed dose are equal (0.2% difference), regardless of air cavity dimensions or iridium source locations in the balloon. The air cavity results in dose increase, due to less photon absorption in the air than in water or solid materials. The extent of the increase depends on the diameter of the air balloon. The average increment is 3.8%, 4.5% and 5.3% for 3.0, 3.5, and 4.0 cm applicators, respectively. In patient cases, the dose to the mucosa is also increased with the air cavity present. The point dose difference between Oncentra Brachy and MC at 5 mm prescription depth is 8% at most and 5% on average.

Conclusions: Except in the vicinity of the air-mucosa interface, the dosimetric difference is not significant enough to mandate tissue inhomogeneity correction in HDR treatment planning.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5978670PMC
http://dx.doi.org/10.1002/acm2.12298DOI Listing

Publication Analysis

Top Keywords

air cavity
20
air balloon
16
balloon applicator
12
vaginal cuff
12
cuff brachytherapy
12
treatment planning
12
air
10
hdr vaginal
8
monte carlo
8
planning systems
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!