Measuring work of breathing (WOB) is an intricate task during high-flow nasal cannula (HFNC) therapy because the continuous unidirectional flow toward the patient makes pneumotachography technically difficult to use. We implemented a new method for measuring WOB based on a differential pneumotachography (DP) system, equipped with one pneumotachograph inserted in the HFNC circuit and another connected to a monitoring facemask, combined with a leak correction algorithm (LCA) that corrects flow measurement errors arising from leakage around the monitoring facemask. To test this system, we used a mechanical lung model that provided data to compare LCA-corrected respiratory flow, volume and time values with effective values obtained with a third pneumotachograph used instead of the LCA to measure mask flow leaks directly. Effective and corrected volume and time data showed high agreement (Bland-Altman plots) even at the highest leak. Studies on two healthy adult volunteers confirmed that corrected respiratory flow combined with esophageal pressure measurements can accurately determine WOB (relative error < 1%). We conclude that during HFNC therapy, a DP system combined with a facemask and an algorithm that corrects errors due to flow leakages allows pneumotachography to measure reliably the respiratory flow and volume data needed for calculating WOB.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.medengphy.2018.02.004 | DOI Listing |
Acc Chem Res
January 2025
Molecular Sensing and Imaging Center, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China.
ConspectusIons are the crucial signaling components for living organisms. In cells, their transportation across pore-forming membrane proteins is vital for regulating physiological functions, such as generating ionic current signals in response to target molecule recognition. This ion transport is affected by confined interactions and local environments within the protein pore.
View Article and Find Full Text PDFJ Opt Soc Am A Opt Image Sci Vis
August 2024
In the pinhole point diffraction interferometer (PPDI), proper alignment between the reflection spot of the tested component and the pinhole is critical to obtain accurate interferograms. At present, adjusting for tilt error requires manual manipulation, and defocus error cannot be corrected. These limitations impede the instrumentation process of PPDI.
View Article and Find Full Text PDFEur Phys J C Part Fields
January 2025
A measurement of the dijet production cross section is reported based on proton-proton collision data collected in 2016 at by the CMS experiment at the CERN LHC, corresponding to an integrated luminosity of up to 36.3 . Jets are reconstructed with the anti- algorithm for distance parameters of and 0.
View Article and Find Full Text PDFHealth Informatics J
January 2025
College of Health Solutions, Arizona State University, Phoenix, AZ, USA.
Show the generalizability of an ingredient-based method to automatically create an up-to-date, error-free, complete list of medication codes (e.g., opioid medications with at least one opioid ingredient) from an ingredient list (e.
View Article and Find Full Text PDFJ Dent Sci
January 2025
School of Dentistry, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Background/purpose: Identifying crestal bone level (CBL) on the buccal and lingual aspects poses challenges in conventional dental radiographs. Given that optical coherence tomography (OCT) has the capability to non-invasively provide in-depth information about the periodontium, this in vitro study aimed to assess whether OCT can effectively identify periodontal landmarks and measure CBL in the presence of gingiva.
Materials And Methods: An in-house handheld scanning probe connected to a 1310-nm swept-source OCT (SS-OCT) system, along with self-developed algorithms were employed to measure the CBL in dental models with artificial gingiva.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!