A 66-year-old male with spontaneous pneumothorax underwent chest tube drainage in other hospital. After tube drainage, chest X-ray showed that the lung fully expanded and an air leakage was not visible. However, clamping the chest tube led to the collapse of the lung, and he transferred to our hospital. A continuous suction unit with pressure and bubbling time history monitoring system was used to detect intermittent air leakages( MS-009T). He underwent video-assisted thoracoscopic surgery. An air leakage from the right lung successfully closed. A new continuous suction unit was useful in detecting an air leakage which could not be confirmed by visual inspection.

Download full-text PDF

Source

Publication Analysis

Top Keywords

air leakage
16
continuous suction
12
suction unit
12
unit detecting
8
detecting air
8
chest tube
8
tube drainage
8
air
5
[usefulness continuous
4
leakage
4

Similar Publications

Ultra-High Sensitivity Methane Gas Sensor Based on Cryptophane-A Thin Film Depositing in Double D-Shaped Photonic Crystal Fiber Using the Vernier Effect.

Sensors (Basel)

December 2024

State Key Laboratory of Metastable Materials Science & Technology and Key Laboratory for Microstructural Material Physics of Hebei Province, School of Science, Yanshan University, Qinhuangdao 066004, China.

Methane gas leakage can lead to pollution problems, such as rising ambient temperature. In this paper, the Vernier effect of a double D-shaped photonic crystal fiber (PCF) in a Sagnac interferometer (SI) is proposed for the accurate detection of mixed methane gas content in the gas. The optical fiber structure of the effective sensing in the sensing SI loop and the effective sensing in the reference SI loop are the same.

View Article and Find Full Text PDF

Intractable pneumothorax secondary to bronchopulmonary fistula is a rare complication in neonates. We present the first report of a newborn with spontaneous pneumothorax and bronchopleural fistula treated with extracorporeal membrane oxygenation (ECMO). Positive pressure mechanical ventilation resulted in persistent air leakage from the bronchopleural fistula.

View Article and Find Full Text PDF

This study aims to determine the optimal structure of the Beam Shaping Assembly (BSA) for an AB-BNCT (Accelerator-Based Boron Neutron Capture Therapy) facility. The aim is to maximize the possible depth of treatment for glioblastoma while ensuring that a treatment time constraint is not exceeded. Approach.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the risk of spontaneous combustion in lignite coal under varying air flows and immersion times.
  • It finds that long-term water-immersed coal shows lower oxygen consumption and heat release at higher temperatures during the primary oxidation process compared to short-term water-immersed coal.
  • In the secondary oxidation phase, long-term water-immersed coal has higher oxygen consumption and heat release rates, while increased air flow and longer immersion times elevate the risk of spontaneous combustion.
View Article and Find Full Text PDF
Article Synopsis
  • Long-distance pressurized pipeline water transmission is at risk of water hammer hazards, which can cause leaks or bursts due to excessive pressure.
  • Modeling calculations using KY PIPE software, paired with real project data, help analyze and address the consequences of pump water hammer stoppages.
  • Installing two-phase check valves, air valves, and water hammer relief valves proves effective in managing pressure and reducing surge tank volume, enhancing pipeline safety for similar projects.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!