Background: Rabbits are particularly sensitive to develop hypotension during sedation or anaesthesia. Values of systolic or mean non-invasive arterial blood pressure below 80 or 60 mmHg respectively are common under anaesthesia despite an ongoing surgery. A reliable method of monitoring arterial blood pressure is extremely important, although invasive technique is not always possible due to the anatomy and dimension of the artery. The aim of this study was to evaluate the agreement between a new oscillometric device for non-invasive arterial blood pressure measurement and the invasive method. Moreover the trending ability of the device, ability to identify changes in the same direction with the invasive methods, was evaluated as well as the sensibility of the device in identifying hypotension arbitrarily defined as invasive arterial blood pressure below 80 or 60 mmHg.
Results: Bland-Altman analysis for repeated measurements showed a poor agreement between the two methods; the oscillometric device overestimated the invasive arterial blood pressure, particularly at high arterial pressure values. The same analysis repeated considering oscillometric measurement that match invasive mean pressure lower or equal to 60 mmHg showed a decrease in biases and limits of agreement between methods. The trending ability of the device, evaluated with both the 4-quadrant plot and the polar plot was poor. Concordance rate of mean arterial blood pressure was higher than systolic and diastolic pressure although inferior to 90%. The sensibility of the device in detecting hypotension defined as systolic or mean invasive arterial blood pressure lower than 80 or 60 mmHg was superior for mean oscillometric pressure rather than systolic. A sensitivity of 92% was achieved with an oscillometric measurement for mean pressure below 65 mmHg instead of 60 mmHg. Non-invasive systolic blood pressure is less sensitive as indicator of hypotension regardless of the cutoff limit considered.
Conclusions: Although mean invasive arterial blood pressure is overestimated by the device, the sensitivity of this non-invasive oscillometric monitor in detecting invasive mean pressure below 60 mmHg is acceptable but a cutoff value of 65 mmHg needs to be used.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5827987 | PMC |
http://dx.doi.org/10.1186/s12917-018-1369-4 | DOI Listing |
Res Social Adm Pharm
January 2025
Department of Pharmacy Practice and Clinical Pharmacy, School of Pharmacy, College of Health Sciences, University of Ghana, P. O. Box LG 43, Legon, Ghana. Electronic address:
Background: Patients with hypertension and other comorbidities have difficulties adhering to their medications which have negative impacts on clinical outcomes. Although some studies have identified strategies to improve medication adherence, a thorough analysis of these interventions will provide synthesized evidence for clinical decision-making and improved health outcomes for patients with hypertension comorbidities.
Aim: To conduct a scoping review on interventions that have been utilised to improve medication adherence in patients with hypertension and other co-morbid conditions.
J Formos Med Assoc
January 2025
Department of Neurology, National Taiwan University Hospital, Taipei, Taiwan. Electronic address:
Controlling hypertension has become an important issue in the elderly population in whom neurological comorbidities are highly prevalent. Most of the large-scale trials focusing on hypertension management in older populations have excluded patients with comorbid neurological disorders. However, this population requires special considerations, as the benefits of antihypertensive agents are mostly uncertain and there is a higher risk of adverse events.
View Article and Find Full Text PDFJ Am Soc Echocardiogr
January 2025
Cardiology Clinic, University Center Serbia, Medical School, University Clinical Center Serbia, University of Belgrade, Serbia.
Background: Heart failure with preserved ejection fraction (HFpEF) is a heterogeneous entity including patients with different phenotypes of near normal, normal, and supernormal left ventricular (LV) function.
Objectives: To assess the value of resting LV elastance (also known as force) with transthoracic echocardiography (TTE) to identify HFpEF phenotypes.
Methods: In a prospective, observational, multicenter study, 2380 HFpEF patients were recruited from July 2016 to May 2024.
Ann Endocrinol (Paris)
January 2025
Assistance Publique Hôpitaux de Paris, Pituitary Unit, Pitié-Salpêtrière Hospital, 75013 Paris, France. Electronic address:
Background: Non-functional adrenal incidentaloma (NFAI) is associated with increased risk of adverse cardiometabolic outcome. Identifying predictors of atherosclerotic cardiovascular disease (ASCVD) may enable more appropriate management strategies in patients with NFAI. We aimed to investigate body composition parameters and ASCVD risk in patients with NFAI.
View Article and Find Full Text PDFSaffron has been traditionally used for various health benefits, but its effects on biomarkers of liver function, kidney function, and blood pressure in diabetes are not well understood. This meta-analysis aims to evaluate the impact of saffron supplementation on systolic blood pressure (SBP), diastolic blood pressure (DBP), fasting blood glucose (FBG), liver enzymes (ALT, AST), and kidney function markers (BUN, creatinine) in patients with diabetes and prediabetes. A comprehensive search was conducted across multiple databases to identify randomized controlled trials (RCTs) assessing saffron/crocin supplementation on glycemic control, hepatic and renal function, and blood pressure regulation in patients with diabetes and prediabetes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!