Background: Different methods have been described for the reconstruction of cranial defects and orbital defects. The complex contouring between the orbital roof and frontal bone creates significant design challenges for prefabricated cranio-orbital reconstructions. In describing the first reported patient of combined skull and orbital roof reconstruction with a single-piece titanium plate cranioplasty, the authors present a new method of combined complex cranio-orbital reconstruction.
Methods: A 63-year-old lady presented with a large, right-sided frontal en-plaque meningioma involving the right orbit and sphenoid wing. Complete resection would require reconstruction of both the skull and the orbital roof. Surgical preplanning involved marking resection margins on a three-dimensional (3D) printed acrylonitrile-butadiene-styrene model. This margin was used to virtually resect the tumor and generate a repaired surface. A titanium plate was then fabricated using hydrostatic pressing into a 3D-printed mold and the orbital roof portion (a reentrant surface) was hand-finished. Lateral canthus and temporalis muscle suspension holes were prefabricated into the cranioplasty plate.
Results: The patient underwent hemicraniectomy and tumor resection guided by a custom-made 3D-printed cutting guide. The surgical defect was reconstructed with the prefabricated titanium plate achieving a good functional and cosmetic result.
Conclusion: Single-piece titanium plate cranioplasty is an effective novel reconstruction method for complex cranio-orbital defects.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/SCS.0000000000004311 | DOI Listing |
Cureus
December 2024
Emergency Medicine, King Chulalongkorn Memorial Hospital, Bangkok, THA.
Introduction BioGlue® (CryoLife, Inc, Kennesaw, GA), despite being claimed to be a safe and harmless sealant, reportedly has several adverse effects including surgical wound dehiscence. This study aimed to examine the factors that may contribute to this unfavorable outcome in cranial surgery. Methods A retrospective cross-sectional analysis was conducted on patients who underwent brain surgery with the use of BioGlue® between January 2015 and December 2022.
View Article and Find Full Text PDFBMC Surg
January 2025
Department of Orthopedics, Nanjing Drum Tower Hospital Group Suqian Hospital, Suqian, China.
Background: To explore the advantages of a lateral tibial locking plate combined with Jail screw fixation in the treatment of anterolateral tibial plateau collapse fracture (ATPCF).
Methods: A retrospective analysis was conducted on patients with ATPCFs admitted to our hospital from February 2019 to February 2023. Twenty-six patients were successfully included, including 15 males and 11 females, with an average age of 58.
J Colloid Interface Sci
January 2025
Liaoning Key Laboratory for Chemical Clean Production, Liaoning Key Laboratory for Surface Functionalization of Titanium Dioxide Powder, Institute of Ocean Research, Institute Environmental Research, College of Chemistry and Material Engineering, Bohai University, Jinzhou 121013 Liaoning, China. Electronic address:
Developing new conductive primers to ensure electrostatic spraying is crucial in response to the call for lightweight production of new energy vehicles. We report a stabilized material, Fe-T/G, of Fe-doped TiO composite graphene synthesized by a simple hydrothermal and electrostatic self-assembly method. The resistivity decreases from 0.
View Article and Find Full Text PDFInt J Oral Maxillofac Surg
January 2025
Stomatological Hospital of Chongqing Medical University, Chongqing, China; Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China; Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China. Electronic address:
The retrospective study aimed to compare the space-maintaining effects of sticky bone (bone graft matrix enriched with injectable platelet-rich fibrin) and titanium mesh for bone augmentation in the aesthetic zone. Patients who underwent single implant placement and had type 2/4 alveolar bone defects (buccal bone wall loss is >50% of the expected implant length) were screened for inclusion in this study. The labial bone plate width was measured at 1, 3, and 5 mm below the apical implant platform on cone beam computed tomography images taken immediately and 6 months after surgery.
View Article and Find Full Text PDFInt J Implant Dent
January 2025
School of Stomatology, Zhejiang Chinese Medical University, Hangzhou, 310053, People's Republic of China.
Purpose: SLM 3D printing technology is one of the most widely used implant-making technologies. However, the surfaces of the implants are relatively rough, and bacteria can easily adhere to them; increasing the risk of postoperative infection. Therefore, we prepared a near-infrared photoresponsive nano-TiO coating on the surface of an SLM 3D-printed titanium alloy sheet (Ti6Al4V) via a hydrothermal method to evaluate its antibacterial properties and biocompatibility.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!