Background: Use of total laboratory automation (TLA) system has expanded to microbiology and hemostasis and upgraded to second and third generations. We herein report the first successful upgrades and fusion of different versions of the TLA system, thus improving laboratory turnaround time (TAT).

Methods: A 21-day schedule was planned from the time of pre-meeting to installation and clinical sample application. We analyzed the monthly TAT in each menu, distribution of the "out of range for acceptable TAT" samples, and "prolonged time out of acceptable TAT," before and after the upgrade and fusion.

Results: We installed and customized hardware, middleware, and software. The one-way CliniLog 2.0 version track, 50.0-m long, was changed to a 23.2-m long one-way 2.0 version and an 18.7-m long two-way 4.0 version. The monthly TAT in the outpatient samples, before and after upgrading the TLA system, were uniformly satisfactory in the chemistry and viral marker menus. However, in the tumor marker menu, the target TAT (98.0% of samples ≤60 minutes) was not satisfied during the familiarization period. There was no significant difference in the proportion of "out of acceptable TAT" samples, before and after the TLA system upgrades (7.4‰ and 8.5‰). However, the mean "prolonged time out of acceptable TAT" in the chemistry samples was significantly shortened to 17.4 (±24.0) minutes after the fusion, from 34.5 (±43.4) minutes.

Conclusions: Despite experimental challenges, a fusion of the TLA system shortened the "prolonged time out of acceptable TAT," indicating a distribution change in overall TAT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6817108PMC
http://dx.doi.org/10.1002/jcla.22400DOI Listing

Publication Analysis

Top Keywords

tla system
20
acceptable tat"
20
"prolonged time
12
time acceptable
12
fusion versions
8
total laboratory
8
laboratory automation
8
laboratory turnaround
8
turnaround time
8
monthly tat
8

Similar Publications

In recent times, innovative surgical robotics have emerged and gained widespread adoption. This study aimed to compare the perioperative outcomes associated with robot-assisted radical prostatectomy (RARP) using three different robotic surgical systems: da Vinci surgical system (DVSS), hinotori surgical robot system (HSRS), and Hugo robot-assisted surgery system (HRASS). Our study involved a retrospective analysis of clinical data from 149 individuals who received RARP from 2022 to 2024, utilizing the DVSS (n = 81), HSRS (n = 52), and HRASS (n = 16).

View Article and Find Full Text PDF

Monitoring a Railway Bridge with Distributed Fiber Optic Sensing Using Specially Installed Fibers.

Sensors (Basel)

December 2024

OlitGlobal Technologies, 3Fl 329 Huaxia Road, Kaohsiung 813016, Taiwan.

This article explores the use of distributed fiber optic sensing (DFOS) technology in monitoring civil infrastructure, with a concrete example of an elevated railway bridge in Taiwan. The field test utilized multiple strain-sensing fibers attached to a 1 km span of a bullet train railway bridge, which were combined to calculate the 3-dimensional bridge deformation. The installed sensing system and continuous measurements enabled quick safety confirmation after earthquakes of Richter scale 6.

View Article and Find Full Text PDF

This study introduces a novel deep learning approach for 3D teeth scan segmentation and labeling, designed to enhance accuracy in computer-aided design (CAD) systems. Our method is organized into three key stages: coarse localization, fine teeth segmentation, and labeling. In the teeth localization stage, we employ a Mask-RCNN model to detect teeth in a rendered three-channel 2D representation of the input scan.

View Article and Find Full Text PDF

Introduction: Risk minimisation measures (RMMs) aim to ensure safe use of medicines, but their implementation in clinical practice is complicated by the diversity of stakeholders whose clinical decision making they seek to inform. Clinical practice guidelines (CPGs) are considered integral in clinical decision making.

Objectives: To determine the extent to which RMMs are included in the relevant CPGs and to describe factors that determine RMM inclusion.

View Article and Find Full Text PDF

Background: There exist multiple regulatory layers for point-of-care (POC) testing to be implemented within Australia. This qualitative analysis sought to understand the pre-market barriers and facilitators to scale-up infectious diseases POC testing in primary care settings at the national level.

Methods: Key informant interviews were undertaken with people (n = 30) working in high- level positions relevant to infectious diseases POC testing in Australia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!