Background: Carotid plaque imaging with MRI is becoming more commonplace, but practical challenges exist in performing plaque imaging with surface coils.
Purpose: To compare the diagnostic performance of a carotid plaque MRI protocol using a standard neurovascular coil (Neurovascular Coil Protocol) to a higher-resolution carotid plaque MRI using carotid surface coils (Surface Coil Protocol) in characterizing carotid plaque.
Study Type: Prospective study comparing two MR techniques in plaque characterization.
Population: Thirty-eight consecutive carotid artery disease patients.
Field Strength/sequence: Patients underwent 3T MRI using 1) a Neurovascular Coil Protocol including the following sequences: 3D-FSE T pre/postcontrast and precontrast 3D IR-FSPGR, and 2) a Surface Coil Protocol using standard multicontrast MRI sequences.
Assessment: Plaque characteristics analyzed by two independent neuroradiologists included intraplaque hemorrhage (IPH), lipid-rich necrotic-core (LRNC), and thin/ruptured fibrous cap (TRFC).
Statistical Tests: Diagnostic performance of the Neurovascular Coil Protocol was compared to the Surface Coil Protocol reference standard using receiver-operating curves.
Results: For IPH, sensitivity, specificity, and area under the curve (AUC) of the Neurovascular Coil Protocol were 91.1% (95% confidence interval [CI] = 78.8-97.5%), 87.0% (95% CI = 66.4-97.2%), and 0.92, respectively. For LRNC without IPH sensitivity, specificity, and AUC were 73.3% (95% CI = 44.9-92.2%), 85.7% (95% CI = 67.3-96.0%), and 0.84, respectively. For TRFC, sensitivity, specificity, and AUC were 35.3% (95% CI = 14.2-61.7%), 97.6% (95% CI = 87.4-99.9%), and 0.66 respectively. Interobserver agreement for IPH, LRNC, and TRFC using the Neurovascular Coil Protocol were k = 0.87 (95% CI = 0.75-0.99), k = 0.54 (95% CI = 0.29-0.80), and k = 0.41 (95% CI = 0.08-0.74), respectively.
Data Conclusion: Our Neurovascular Coil Protocol has high sensitivity, specificity, and accuracy in identifying IPH and LRNC but is limited in assessment of TRFC.
Level Of Evidence: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1264-1272.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jmri.25984 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!