Slips, trips and falls are leading causes of fireground injuries. A functional balance test (FBT) was used to investigate the effects of self-contained breathing apparatus (SCBA) size and design, plus firefighting work cycle. During the FBT, subjects walked along a narrow platform and turned in defined spaces, with and without an overhead obstacle. Thirty firefighters wore three varying-sized standard SCBAs and a low-profile prototype SCBA during three simulated firefighting work/rest cycles. Firefighters were tested pre- and post-firefighting activity (one bout, two bouts with a 5-min break, or back-to-back bouts with no break). Subjects committed more errors and required longer completion times with larger SCBAs. Use of the prototype SCBA lead to lower times and fewer errors. Performing a second bout of firefighting increased completion time. Firefighters need to consider how SCBA and amount of physical activity on the fireground may influence balance in order to reduce the risk of injury.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apergo.2018.01.006DOI Listing