Purpose: Validating deformable multimodality image registrations is challenging due to intrinsic differences in signal characteristics and their spatial intensity distributions. Evaluating multimodality registrations using these spatial intensity distributions is also complicated by the fact that these metrics are often employed in the registration optimization process. This work evaluates rigid and deformable image registrations of the prostate in between diagnostic-MRI and radiation treatment planning-CT by utilizing a planning-MRI after fiducial marker placement as a surrogate. The surrogate allows for the direct quantitative analysis that can be difficult in the multimodality domain.
Methods: For thirteen prostate patients, T2 images were acquired at two different time points, the first several weeks prior to planning (diagnostic-MRI) and the second on the same day as the planning-CT (planning-MRI). The diagnostic-MRI was deformed to the planning-CT utilizing a commercially available algorithm which synthesizes a deformable image registration (DIR) algorithm from local rigid registrations. The planning-MRI provided an independent surrogate for the planning-CT for assessing registration accuracy using image similarity metrics, including Pearson correlation and normalized mutual information (NMI). A local analysis was performed by looking only within the prostate, proximal seminal vesicles, penile bulb, and combined areas.
Results: The planning-MRI provided an excellent surrogate for the planning-CT with residual error in fiducial alignment between the two datasets being submillimeter, 0.78 mm. DIR was superior to the rigid registration in 11 of 13 cases demonstrating a 27.37% improvement in NMI (P < 0.009) within a regional area surrounding the prostate and associated critical organs. Pearson correlations showed similar results, demonstrating a 13.02% improvement (P < 0.013).
Conclusion: By utilizing the planning-MRI as a surrogate for the planning-CT, an independent evaluation of registration accuracy is possible. This population provides an ideal testing ground for MRI to CT DIR by obviating the need for multimodality comparisons which are inherently more challenging.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5849829 | PMC |
http://dx.doi.org/10.1002/acm2.12296 | DOI Listing |
Sci Rep
August 2024
Department of Radiation Oncology, Klinikum Rechts der Isar, Technische Universität München, Ismaninger Straße 22, 81675, Munich, Germany.
J Med Imaging Radiat Sci
December 2024
Cancer Division, University College London Hospitals NHS Foundation Trust, London, UK.
Introduction: The inter-fraction motion of pelvic ± para-aortic (PA) nodal volumes in prostate cancer patients with involved nodes is yet to be quantified and the optimal IGRT strategy for these patients is currently unknown.
Methods: A single-centre retrospective evaluation was performed investigating inter-fraction motion in the prostate and involved nodal volumes of patients receiving pelvic ± PA nodal irradiation. Patients were selected for inclusion if they; were undergoing prostate + pelvic node +/- PA node radiation for prostate cancer with involved lymph nodes and had received daily online CBCT scans.
Front Oncol
June 2024
Department of Radiation Oncology, Davidoff Cancer Center, Rabin Medical Center, Petah Tikvah, Israel.
Introduction: Precise patient positioning with image guidance (IGRT) is essential for safe prostate radiotherapy. We present the first report of utilizing a CT-visible hydrogel spacer, used to decrease rectal radiation dose, as a surrogate fiducial marker to aid in daily IGRT with cone-beam CT (CBCT) in stereotactic radiotherapy (SABR) for prostate cancer.
Materials And Methods: Prior to CT simulation, patients underwent placement of three intraprostatic gold fiducial markers and radiopaque hydrogel spacer per standard practice.
Asian Pac J Cancer Prev
January 2024
Department of Anesthesia and Critical Care, Sri Guru Ram Das Institute of Medical Sciences and Research, Amritsar, India.
Background: Carcinoma of the cervix is a globally significant cause of morbidity and mortality among women. Concurrent chemoradiotherapy, a standard approach for locally advanced cervical cancer, invariably involves pelvic irradiation. Although this strategy is effective, it inevitably affects the pelvic bone marrow, a crucial hematopoietic site, and leads to hematological toxicity The potential of IMRT to spare bone marrow in pelvic irradiation settings has been an area of significant interest, with the aim to mitigate the hematological toxicity associated with pelvic radiotherapy.
View Article and Find Full Text PDFStruct Heart
November 2023
Heart Center Lucerne, Cardiology, Luzerner Kantonsspital, Lucerne, Switzerland.
Background: Motion artifacts in planning computed tomography (CT) for transcatheter aortic valve implantation (TAVI) can potentially skew measurements required for procedural planning. Whether such artifacts may affect safety or efficacy has not been studied.
Methods: We conducted a retrospective analysis of 852 consecutive patients (mean age, 82 years; 47% women) undergoing TAVI-planning CT at a tertiary care center.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!